Find which Actron Air controller you have, NEO, LM7-2, LM24-2 or LC7-2, then follow ActronAir’s own manuals to use zones, timers and the 7 day clock, choose heating settings, read the display symbols and use NEO Connect or ActronConnect.
An Actron Air wall controller manual only helps if it matches your controller, and ActronAir has made several. So this page starts by helping you tell the controllers apart. Once you know which controller is on your wall, each task section below says whether it applies: zones, timers, heating settings, the display symbols and the phone app.
The ActronAir facts come from ActronAir’s own documents: the LM7-2 and LM24-2 Wall Controller Operation Manual, document 0525-079, the LC7-2 Wall Control Operation Manual, document 0525-080, the NEO operation manual insert, document 9590-3033-02, with its online user guide, the ActronConnect User Guide, document 9590-1002, the Serene Series 2 Remote Controller Operation Manual, document 9590-4010, and the NEXUS Touch product page. The licence and electrical safety points come from ABLIS and Energy Safe Victoria.
Which Actron Air controller do I have?
First, find the model number. The LM7 and LM24 manual says the wall controller’s model number is on the front of the controller. The air conditioner’s own model and serial number are on the access panel of the outdoor unit, at the bottom left corner.
NEO touch controller
The Actron Air NEO controller is a touchscreen. The NEO insert describes a temperature dial in the middle, with mode selection, fan speed, the main menu, a zone menu, inside conditions and an options menu around it. Options include Away Mode, Quiet Mode, Continuous Fan and Turbo Mode. NEO does not come with a full printed manual. Instead, the insert points to an online user guide, reached by scanning a QR code or by holding a phone with NFC above the power button.
LM7-2 and LM24-2 wall controllers
By contrast, these are button controllers with an LCD display, in white or grey. Model names end in W for white or G for grey, such as LM7-2W. The manual says both have the same buttons and functions, except three. The LM24-2 has no Program button, no Exit button and no Repeat button. So the LM7-2 has a 7 day time clock, and the LM24-2 does not.
Both have up to 8 zone buttons with on and off indicators, and an NFC tag that lets a phone open the user manual.
LC7-2 wall control
The LC7-2 has its own operation manual, document 0525-080. It covers on and off, set temperature, operating mode, timers, backlight, a program menu, a filter timer and an after hours function. It also has an NFC tag.
NEXUS Touch controller
ActronAir’s NEXUS Touch product page describes it as a touch controller and an upgrade for ActronAir ASPIRE and UltraSlim ducted systems. The page says up to two NEXUS Touch controllers can connect to one of those systems.
The Actron Air WiFi controller option
Phone control depends on the system. A NEO system comes with the NEO Connect app as standard. Older systems with an ActronConnect Module, called ACM, use the ActronConnect app. The ActronConnect guide says the module normally sits in the roof space. The app section below covers both.
How do I control zones on an Actron Air system?
How you switch zones depends on the controller.
On an LM7-2 or LM24-2
- Press a zone button to turn that zone on or off.
- The zone’s light shows when it is on.
The manual says that by default at least one zone must be left on, and the controller will not let you turn off the last one. Switching the last zone off moves control to Zone 1 automatically. It adds that some models can turn off all zones, and to ask your installer.
Which temperature the controller reads
The LM7 and LM24 manual describes integrated zoning. The controller can choose a remote temperature sensor depending on which zones are on. Its example is a two storey house with only the downstairs zone on, where the downstairs sensor controls the temperature. To check the room temperature, press the up or down button and it shows for 3 seconds.
On a NEO
The NEO user guide says to touch Zones on the main screen, then touch a zone to turn it on or off. An active zone shows ON, and an inactive one is greyed out and shows OFF. Zone names can be changed under System Settings, then Zone Settings.
On compatible systems, YourZone lets you adjust each enabled zone’s opening in 5 percent steps. The guide warns that a small caret symbol appears if the total across zones is not 100 percent.
In the ActronConnect app
The ActronConnect guide says to press a zone’s on and off button to close it, and the zone turns grey. At least one zone must stay on. It also says not to press zone buttons in quick succession, because the system handles one command at a time. For the idea behind zoning, see the guide to how zoned air conditioning works.
How do I set the timer on an Actron Air controller?
Countdown timers on the LM7-2
Note that the OFF timer needs the system on, whereas the ON timer needs it off.
- Press TIMER to enter the timer menu.
- Use up or down to choose the hours until the system turns off, or on. Timers go up to 24 hours in half hour steps.
- The TIMER indicator shows while a timer is active. Press TIMER again to cancel it.
The LM7-2 seven day time clock
The 7 day time clock turns the system on and off at set times on each day. Each day can have 2 events, and each event has an on time and an off time.
- Set the time and day first: press PROG 3 times, then set the hours, minutes and day, pressing PROG after each.
- Activate the clock: press PROG twice, press the on button until ON flashes, then press EXIT. The TIME CLOCK indicator lights.
- Program events: press PROG until EVENT 1 and the day show, set the on time, press PROG, set the off time, press PROG.
The manual warns that pressing EXIT before moving to the next event loses the time you just set. An on time can be set up to 11:45 pm, and an off time up to 9:00 am the next morning. Programming Event 1 past midnight cancels Event 2. The REPEAT button copies the previous day’s events.
Also, during a power failure, a backup battery keeps the clock and day. To clear every program back to factory settings, turn the controller off, press and release PROG, then hold the off button for 3 seconds. All indicators light for about a second.
On a NEO
The NEO user guide has two options under the Menu. Timer counts down to turn the system on or off. Schedules let you name a schedule, pick days, a time, comfort settings and zones. The guide says that on systems with more than one NEO controller, schedules are only available through the C1 controller.
In the ActronConnect app
Likewise, the app’s timer sets on or off in hours and half hours. The guide notes the app timer is not synchronised with the wall controller’s timers. If both are set, the later one decides when the system turns off.
What are the best Actron Air settings for heating?
The LM7 and LM24 manual has a section of operating tips, and it gives clear numbers. Here is what ActronAir says for winter.
The recommended setting
The manual says the normal setting recommended is 22°C for both summer and winter. It adds that lowering the set point by 1°C in winter can save about 10 percent on electricity costs. On the LM7-2, the heating range is 16 to 30°C.
Overnight and cold mornings
If you leave the system running overnight, the manual suggests lowering the set point by 2 to 4°C from your normal setting. That stops the house getting too cold, so it warms faster in the morning. Another option it gives is to start the system a couple of hours earlier than usual. When it is about 7°C or colder outside, it says supplementary heating may help.
The fan in heating
Continuous fan, shown by the CONT indicator, suits cooling. However, the manual says it can cause cool drafts when heating. For heating, press the fan button until CONT goes off, so the indoor fan cycles with the outdoor unit.
Doors, curtains and zones
Keep curtains and windows closed, stop drafts at doors, and turn off zones you are not using. The manual says that gives more heating capacity where you need it. Ask your installer how many zones must stay open on your system.
What is normal when heating
The manual lists hot start: when heating starts, the indoor fan waits a short time so the coil warms up first. Air may not flow for about 15 seconds. During a defrost, the HEAT indicator flashes every 10 seconds, the indoor fan may stop for several minutes, and steam may rise from the outdoor unit.
Locking the temperature range
In addition, the LM7 and LM24 can set upper and lower temperature limits, for example 20 to 25°C, so no one sets it too high or too low. The defaults are 30°C and 16°C. The manual recommends not going outside those defaults.
What do the symbols on an Actron Air remote mean?
ActronAir publishes separate manuals for its handheld remotes, so the symbols depend on the model. This section covers the Serene Series 2 remote first, then the wall controller screen and the app.
Serene Series 2 remote symbols
The RC-02 remote for Serene Series 2 systems, models WRE-026CS to WRE-085CS, has its own operation manual, document 9590-4010. Its Remote Screen Indicators page lists these:
- Transmission indicator: lights up when the remote sends a signal to the indoor unit.
- Mode icons: AUTO, COOL, DRY, HEAT and FAN show the current mode.
- Timer ON and timer OFF clocks: show that an on or off timer is set.
- Fan bars: show the fan speed, from Quiet through LOW, MED and HIGH to AUTO. The manual says the speed cannot be adjusted in AUTO or DRY mode.
- ECO and GEAR: show that those energy saving features are on.
- QUIET, BOOST and the louvre symbols: show quiet operation, boost and the swing settings.
- Padlock: the remote’s buttons are locked. To unlock, hold Boost and Humidity together for 2 seconds.
- Battery symbol: the manual lists a flashing battery as low battery detection.
- Information row: small icons for Breeze Away, the ECO Intelligent Eye, Active Clean, Fresh, Sleep, Follow Me and AP Mode, shown while those functions are in use.
The manual also says the number display goes blank in FAN mode, because the set temperature does not apply there. If your remote looks different, find the manual for its model on ActronAir’s website.
LM7-2 and LM24-2 display symbols
| Symbol | Meaning in the manual |
|---|---|
| RUN | The outdoor unit is running. It flashes if the unit is on a delay |
| AUTO | The system picks heating or cooling itself |
| HEAT, COOL | The operating mode. HEAT flashes every 10 seconds during defrost |
| CONT | The fan is set to run continuously |
| Low, medium, high fan bars | The fan speed |
| FILTER | It is time to check the filter |
| TIMER | A timer is running |
| Flashing degree sign and room temperature indicator | The current room temperature is showing |
| SET | A time or time clock setting is being changed |
| Lock symbol | The backlight is being adjusted or turned on or off |
| EVENT, 1, 2, ON, OFF | Time clock programming, LM7-2 only |
If E followed by digits shows, the manual says to note the digits and contact your installer. Those codes are explained in the Actron Air fault codes guide.
Colours in the ActronConnect app
Similarly, the ActronConnect guide colour codes the screen: blue for cooling, red for heating, green for fan only, purple for auto and grey for off. It also shows an ESP indicator on some models, and warns that using the app overrides ESP mode. The wall controller is then needed to turn ESP back on.
Which Actron Air app do I use, and how does it work?
ActronAir uses two app names, so match the app to your system.
NEO Connect for NEO systems
The NEO insert says the NEO Connect app comes as standard and lets you control the system from a phone or tablet. The online guide says to download it from the App Store or Google Play, then connect your NEO Connect account under Account Settings on the controller. It notes the app can run the timer on systems with a cloud connection.
ActronConnect for systems with a module
The ActronConnect User Guide covers the ACM-2 module. The app’s menus are Home, Zones, Timer, Settings and Info. Settings holds your account, the air conditioner’s settings, the number of zones and app settings. The Info screen shows the app version, and the guide says to always check for the latest version.
While the module processes a command, a scanning symbol shows. The guide says to wait for it to finish before pressing anything, or the process may take longer or stop. The module itself sits in the roof space, so leave its installation and wiring to your installer.
Where can I find the manual for my Actron Air controller?
ActronAir publishes its controller manuals on actronair.com.au. The Actron Air controller manual for the LM7-2 and LM24-2 is document 0525-079. The LC7-2 manual is 0525-080. NEO owners use the online user guide at neo.actronair.com.au, reached from the QR code on the insert or by NFC. The LM7, LM24 and LC7 controllers also carry an NFC tag that opens the manual on a phone.
Care the manuals ask for
Wipe the controller with a soft dry cloth, never spray liquid on it, and keep its temperature sensor free of dust. Clean the air filter every 4 weeks, or when the filter light shows, then press ON and OFF to clear the light. The manual also says never to run the system without a return air filter. The guide to cleaning a ducted aircon filter walks through it.
The power rule for the outdoor unit
The manual says the main power to the system should stay on at all times, to protect the compressor. If power has been off for 6 hours or more, wait 2 hours after it returns before starting the system.
When should I stop and call a technician?
The manuals say never to remove access panels or guards, never to pull apart the controller, and that installation and servicing are for a qualified technician. They recommend servicing every 12 months for homes. Refrigerant work needs a refrigerant handling licence, according to the Australian Government’s ABLIS service, and Energy Safe Victoria says unqualified electrical work is extremely dangerous and illegal. For a fault the checks on this page do not fix, see the air conditioning repair page. For more symptoms, see the Actron Air troubleshooting guide or the Actron Air owner guide.
What is the short version for Actron Air controllers?
Find the model number on the front of the controller first. A touchscreen with a dial is NEO, with its guide online. LM7-2 and LM24-2 are button controllers, and only the LM7-2 has the 7 day clock. Keep at least one zone open. For heating, ActronAir recommends 22°C, a lower setting overnight and fan cycling rather than CONT. Use NEO Connect on NEO, and ActronConnect on systems with the ACM module.