In short

A Breezair evaporative cooler is a premium rooftop cooler made by Seeley International, usually run from a MagIQtouch wall controller. Owners should prepare the cooler before summer, drain and clean it after summer, keep windows open while it runs and book a service after the first year and then every two years, as the owner manual sets.

A Breezair evaporative cooler is easy to forget about. It sits quietly on the roof, cools the house on hot dry afternoons and asks for very little in return. Then one day the air turns warm and damp, the controller flashes a service message, or a musty smell drifts from the vents.

This guide is for owners who want to understand the cooler above their heads. It explains how Breezair coolers work, how to find your model and manual, what the controller can do and the simple care that keeps the system fresh.

We also summarise the faults owners search for most and link to fuller answers. So start here, then follow the link that matches your situation.

How a Breezair cooler cools your home

Evaporative cooling uses a simple natural process. A fan draws hot outside air through wet pads, the water evaporates, and the air leaves the pads noticeably cooler. Ducts then carry that air to outlets in each room.

Why open windows matter

Unlike refrigerated systems, an evaporative cooler supplies fresh outside air all the time. That air needs a way out, so you must leave some windows or doors open while the cooler runs. If the house stays sealed, the air stalls and the rooms feel humid instead of cool.

Where it works best

Evaporative cooling performs best in hot, dry weather, such as inland summers. On muggy coastal days, the air already holds plenty of moisture, so less water evaporates and cooling drops. This is normal behaviour, not a fault.

Breezair and its sister brand

Seeley International, an Australian manufacturer, makes Breezair. It positions Breezair as its premium evaporative range and Braemar as its conventional range. If your roof has a Braemar cooler instead, see our Braemar owner guide.

Breezair models and how to identify yours

Knowing your model helps with every manual search, parts order and service booking. Breezair has released several series over the years.

Current ranges

Seeley lists several Breezair ranges for homes. Extraordinaire is its newest, highest performance range, while Supercool and Icon round out the lineup.

Older Breezair models

Many homes still run earlier coolers. Owner manuals on the Seeley website cover series with codes such as EXQ, EZQ, EXS, EXVQ, TBQ and TBS. So old Breezair models are well supported, at least when it comes to paperwork.

Reading the label

The model and serial numbers sit on a label on the cooler. Seeley also asks owners to stick a copy of that label on the back cover of the owner manual. Check the manual or your purchase paperwork first, before anyone climbs onto the roof.

Our page on identifying your Breezair model explains where else to look and what the letters and numbers mean.

The controller and the Breezair manual

Most recent Breezair coolers use the MagIQtouch wall controller. Seeley shares this touch screen controller across its Breezair and Braemar ranges.

What MagIQtouch can do

According to the Breezair owner manual, MagIQtouch includes several water functions alongside normal fan and temperature control.

  • Pad Flush turns the cooler off and runs the pumps for a set time, which helps clear new pad odours.
  • Manual Drain turns the cooler off and empties the water tank.
  • Drain and Dry lets you schedule a daily tank drain followed by an hour of fan only running.

Seeley also promotes a Wi Fi smart app and voice control for MagIQtouch. As a result, you can check the cooler status and change settings from your phone.

Finding the right manual

Seeley hosts owner manuals for current and older products on its product manuals page. Filter by Breezair, then search for your model code. You will also find separate manuals for the controller.

For help with buttons and menus, our Breezair wall controller guide covers everyday use in more detail. If an older controller has failed, a Breezair controller replacement usually needs a technician to confirm the new unit suits your cooler.

Breezair technology in plain words

Seeley lists several features on its Breezair pages. Here is what each one means for owners.

Chillcel pads

Breezair coolers use Chillcel pads, which Seeley describes as superior for cooling capacity. These are rigid, honeycomb style pads. The owner manual notes that some models use pads of a different thickness, so always match replacement pads to your exact model.

Water management

Breezair coolers include a Tornado pump and an Auto Cleanse function that drains the water automatically. Many models also use a WaterMiser system, which watches water quality and drains the tank when minerals build up. The manual says WaterMiser should be switched off for bore water supplies, while the factory setting is HI.

Drain valve

The Breezair drain valve opens to flush salty water from the tank. Some water running across the roof or into the gutter is therefore normal. However, constant flowing water with the cooler off suggests a fault worth checking.

Caring for your Breezair through the year

Breezair owner manuals split owner care into tasks before summer and tasks after summer. Following them keeps the cooler fresh and protects your warranty.

Before the first hot day

  1. Turn the water supply back on to the cooler.
  2. Remove the pad frames and gently wash off dust that built up over winter.
  3. Restore power and run the cooler on a cooling setting.
  4. Watch the pads to confirm water spreads evenly across every one.
  5. Note any odd noises or smells and report them to a service agent.

When summer ends

  • Turn off the water supply to the cooler.
  • Drain the tank completely.
  • Clean the tank, the pump filter and the salinity probe if fitted.
  • Close any ceiling outlets or fit a winter seal if your installer supplied one.

Never wash Chillcel pads with high pressure water, because it can damage them. Many owners hand the end of season work to a technician, since it happens on the roof.

Working safely on the roof

Roof work causes serious injuries every year. If you are not confident on a ladder, or the roof is steep, wet or high, leave the job to a trained technician. Always turn off the power at the isolator before opening the cooler.

Common Breezair evaporative cooler faults

Most problems with a Breezair evaporative cooler come down to water, air or the controller. Here are the ones owners search for most, with links to fuller help.

Not cooling properly

The Breezair manual lists three usual reasons for weak cooling. These are dry pads, too little exhaust through open windows and high humidity. So check the water tap, open a few more windows and compare the day with the weather forecast.

Our answer on a Breezair cooler that is not cooling goes through each check step by step.

Service messages on the controller

A Breezair evaporative cooler logs faults as numbered service codes. Breezair service 2 is one of the codes owners search for most. The owner manual for your model explains each number, and our Breezair troubleshooting guide covers the common ones.

Owners also ask about a Breezair service code reset. First fix the cause, such as turning the water back on, then follow the reset steps in the manual for your controller. If the same code returns, call an authorised service agent.

Smells, cycling and leaks

  • Musty or new pad smells often ease after a Pad Flush or a tank drain.
  • A cooler that keeps turning on and off points to an internal fault, so the manual says to contact a dealer or service agent.
  • Water dripping from ceiling outlets suggests a blocked tank drain, a stuck float valve or a damaged seal.

Getting the most comfort from your cooler

A few small habits change how cool the house feels. They cost nothing and suit every Breezair model.

Plan the airflow

Think of the cooler as a gentle wind that enters through the ceiling and leaves through the windows. Open windows in the rooms you want to cool, and keep doors to unused rooms closed. That way the cool air flows where you need it instead of escaping through the nearest gap.

Time it well

Start the cooler in the morning, before the house soaks up heat. In addition, run a higher fan speed during the hottest hours, then drop it back in the evening. On very humid days, use a fan only setting for air movement instead of adding more moisture.

Keep the outlets clean

Ceiling outlets collect dust over summer, which reduces airflow and spreads grime. Wipe them with a damp cloth once or twice a season. Also check that nothing blocks the outlets, such as tall cupboards or stored boxes.

What owners can and cannot do safely

Some Breezair cooling repair work is fine for a careful owner, while other jobs belong with a trained person. Knowing the line keeps you safe and protects your warranty.

Safe owner tasks

  • Checking the water tap, power isolator and controller settings
  • Using Pad Flush, Manual Drain or Drain and Dry on MagIQtouch
  • Opening more windows and cleaning ceiling outlets
  • Reading the service code and noting it down for the technician

Jobs for a technician

Electrical repairs, motor and pump replacement, controller wiring and anything inside the cabinet belong with an authorised service agent. Roof access also carries real risk, so most pad changes and full cleans suit a professional too. If in doubt, ask Seeley which service agent covers your area.

Servicing and Breezair repairs

Seeley sets professional servicing as part of the maintenance schedule in each owner manual. Skipping it can affect your warranty cover.

How often to service a Breezair evaporative cooler

The EXQ, EZQ and EXS owner manual asks for a service after the first year, then every two years. Coolers that run more than twelve hours a day need more frequent checks, every six and twelve months. Dusty or hard water areas may also justify a shorter gap.

What a service usually includes

  • Inspecting and cleaning the pads, tank and water distribution
  • Testing the pump, drain valve and float valve
  • Checking the fan, motor and electrical connections
  • Confirming the controller and any service codes
  • Looking at the roof seals and duct connection

The service cost depends on roof access, cooler size, pad condition and any parts needed. Our guide to Breezair service costs and timing explains what drives the price, so you can ask the right questions.

Parts and repairs

Genuine Breezair parts come from Seeley International and its authorised service agents and spare parts distributors. A Breezair parts diagram in the service documents helps a technician match the exact part. Our page on Breezair evaporative cooler parts explains how to order the right ones.

Contacting Seeley

Seeley lists its service and warranty line as 1300 650 644. You can also request a service through the Seeley website. Register your warranty with Seeley soon after installation, and keep your purchase paperwork with the owner manual.

Frequently asked questions about Breezair coolers

Who makes Breezair evaporative coolers?

Seeley International, an Australian company, makes Breezair. It also makes the Braemar range. Warranty, servicing and parts for both brands run through Seeley and its service agents.

How often should a Breezair cooler be serviced?

The owner manual asks for a professional service after the first year, then every two years for typical home use. Coolers that run long hours each day need more frequent checks. Owners should also complete the before and after summer tasks.

Where can I find a Breezair evaporative cooler manual?

Seeley hosts owner manuals on its product manuals page. Filter by Breezair and search using the model code from the cooler label or your paperwork. Controller manuals sit on the same page.

Can I replace Breezair evaporative cooler pads myself?

Pad replacement involves working on the roof and matching the right pad thickness to your model. Most owners book a technician for safety reasons. If you do it yourself, turn off the power and water first and follow the manual.

Why does my Breezair cooler make the house feel humid?

Usually there are not enough open windows for the air to escape. Humid weather also limits how much cooling any evaporative system can deliver. Open windows on the far side of the house and try a higher fan speed.

What to do next

A Breezair evaporative cooler rewards a little regular attention. Know your model code, keep the owner manual handy and learn the water functions on your MagIQtouch controller.

Prepare the cooler before summer, drain and clean it after summer and book servicing at the intervals your manual sets. If service codes keep returning or the pads stay dry, call an authorised service agent.

For specific questions, explore the Breezair answers listed above this guide. For a broader view of the whole category, our evaporative cooling guide is a useful next step.

Every Breezair question we answer