You asked
We'll solve it.Opening your answer
General · Sizing & Buying

What Size Air Conditioner Do I Need? Room Size, Heating and the H2 Rating

Reading time 11 minUpdated 28 Nov 2026For Australian homesBy Checked against sources by our review team, 28 Nov 2026
Short answer

What size air conditioner do I need? Start with floor area using Solar Victoria’s and Samsung’s published guides, adjust for orientation, insulation and climate, then check the heating capacity, including the H2 figure measured at 2°C outdoors, before the installer confirms it.

What size air conditioner do I need? Start with the room’s floor area, then adjust for everything else about the room, and check the heating figure separately from the cooling one. This guide sets out the size guides that a government body and a manufacturer publish, the factors they say change the answer, and how to read the heating capacity figures on the label, including the H2 rating.

There is no sizing calculator here, and no invented numbers. The text credits every table and rule to the body that published it. Treat them as a starting point, and let the installer assess your actual home before you buy.

What size air conditioner do I need for my room?

Size means capacity, measured in kilowatts. Samsung’s Australian guide makes the point that capacity refers to output, not to how big the unit looks. Two published guides give a starting point by floor area.

Solar Victoria’s guide

Solar Victoria’s buyers guide for home heating and cooling upgrades gives a rough capacity guide, which it credits to CHOICE:

Room sizeApproximate capacity
Up to 20 m²About 2 to 2.5 kW
20 to 40 m²About 2.5 to 5 kW
40 to 60 m²About 4 to 6 kW
60 to 80 m²About 5 to 7 kW
Over 80 m²About 6 to 9 kW

Samsung’s guide

Samsung Australia publishes its own space capacity guide for its air conditioners:

CapacityRoom sizeSamsung’s example
2.5 kW9 to 24 m²Small bedrooms and home offices
3.5 kW25 to 33 m²Medium bedrooms
5.0 kW34 to 47 m²Large bedrooms and medium living areas
7.0 kW48 to 65 m²Large living areas
8.0 kW66 to 82 m²Open plan living areas

Samsung says its table is a guide only, and that it applies to its Australian products.

How to measure the room

Multiply the room’s length by its width in metres to get the floor area in square metres. For an L shaped or open plan space, measure it as the areas you want the unit to heat and cool, then add them up. Note anything unusual too, such as a high ceiling or a wall of glass, because the guides below say those change the answer.

What changes the size I need?

Floor area is only the first step. Both sources list other factors that can push the answer up or down.

The factors Samsung lists

  • Which way the room faces.
  • How the room is used.
  • The room’s dimensions.
  • Construction materials and insulation.
  • Equipment in the room and other heat loads.

Climate

Solar Victoria says the energy needed to heat and cool a house depends on the climate where you live. Its example is close to home: Ballarat and Alpine areas are much cooler in winter, so they need more heating than other Victorian climates. The same room can need a different unit in a different place.

Why the right size matters

Solar Victoria explains the risk on both sides. Models too powerful for the room may run frequent short cycles to reach the set temperature. That can leave the room too hot or cold, dry the air poorly, raise running costs and add wear. On the other hand, underpowered models may have to run at maximum output more often, which can dry the air too much and cause excessive wear.

Its conclusion is that the right size for the space maximises efficiency. It also says to take advice from the supplier when they assess your home.

What size split system do I need?

The room guides above apply to a split system too. In addition, the ACT Government’s buyers guide to reverse cycle systems, on its Climate Choices site, adds a sense of scale.

Where one split system fits

The ACT guide says larger split systems can serve areas of up to 80 square metres, and would suit apartments or the living areas of smaller houses. It adds that you can zone several split systems so that only occupied areas get heating or cooling.

When to look past one split

For bigger homes, the ACT guide says ducted or multi head systems suit larger houses. It says that below 180 square metres, split systems are usually the more cost effective choice. Above that, it suggests considering ducted or multi head systems. It also notes that installing them in a large house may need an upgrade to 3 phase power, which the installer confirms.

For whole of home systems, see the guide to what size ducted aircon you need.

Comparing models of the same size

The ACT guide says to compare energy ratings only between systems of similar size or capacity, and to choose the highest energy rating you can afford. Pick the capacity first, then compare efficiency within it.

Check the bedroom and the living room separately

Each room has its own floor area, use and sun. So size each split for the room it will serve. Samsung’s own examples split the same way, from small bedrooms at 2.5 kW to open plan living areas at 8.0 kW.

What size split system do I need for heating?

A reverse cycle split has two capacity figures: one for cooling and one for heating. The room guides above are mostly about cooling. Samsung’s page, for example, sizes by cooling output and does not mention heating. So if heating matters to you, check the heating figure as well.

Heating output falls as it gets colder

The manufacturers’ manuals say heating gets harder on cold days. Fujitsu’s ASTG09KMTC and ASTG12KMTC operating manual explains that the unit takes heat from the outdoor air, so its heating performance drops as the outdoor temperature drops. If heating feels short, Fujitsu suggests using another kind of heater alongside it. Actron Air’s wall controller manual says supplementary heating may help when it is about 7°C or colder outside.

Smaller units and heating

The ACT guide makes a related point. It says smaller systems tend to have better efficiency than larger ones, but will not have as good a heating output. So a unit sized tightly for summer cooling may feel short of heat in a cold climate.

What this means for sizing

In a cold area, look at the heating capacity figures on the label for the room you want to heat, not just the cooling figure. Solar Victoria’s point about Ballarat and Alpine areas needing more heating applies here. The next section explains which heating figure to look at. For how a reverse cycle unit heats, see what a reverse cycle air conditioner is.

What does the H2 heating capacity rating mean on a split system?

The H2 heating capacity rating on a split system’s label is one of the heating test conditions of the Zoned Energy Rating Label. Mitsubishi Electric Australia’s guide to the label explains it.

The three capacity figures on the label

FigureIndoor temperatureOutdoor temperature
Cooling capacity (T1)27°C35°C
Heating capacity (H1)20°C7°C
Heating capacity (H2)20°C2°C

Mitsubishi Electric says the label measures the capacities under the T1, H1 and H2 conditions of the Australian and New Zealand standard AS NZS 3823.1.1.

Why H2 matters in winter

H2 shows the heating capacity at an outdoor temperature of 2°C, rather than 7°C. So it tells you the unit’s heating capacity at a colder outdoor temperature than H1. The ACT Government’s buyers guide says to look for the H2 figure, saying it shows whether a unit is well suited to Canberra’s winters.

How to use it

  1. Find the heating capacity at H2 on the label, in kilowatts.
  2. Compare it with the heating you need for the room, as the installer assesses it.
  3. Compare H2 figures only between units of similar size, as the ACT guide advises for ratings.

How do I read the heating stars on the label?

The same label shows efficiency as well as capacity. Mitsubishi Electric’s guide says it divides Australia and New Zealand into three climate zones: hot, average and cold. Blue stars show cooling efficiency and red stars show heating efficiency, for each zone. The more stars, the more efficient. The ACT guide describes the colours the same way.

Which units carry it

The ACT guide says new ducted reverse cycle systems with a cooling capacity under 30 kW will need a Zoned Energy Rating. Mitsubishi Electric describes it as the label for split system air conditioners.

The steps Mitsubishi Electric suggests

  1. Work out the size of air conditioner the room needs.
  2. Find your climate zone on the label’s map.
  3. Compare star ratings in your zone, and choose on efficiency and energy use.
  4. Work out yearly running costs with the Energy Rating calculator.

The label also shows yearly energy use. The guide to how much electricity an air conditioner uses explains how to turn that into a cost.

Does the outdoor temperature range matter when choosing a size?

Yes, because each unit is designed for a range of outdoor temperatures, and capacity changes across that range. The manuals print these ranges, so check them for the climate you live in.

Ranges from the manuals

ManualCooling, outdoorHeating, outdoor
Toshiba Seiya, RAS-07 to 18E2KV2G-AMinus 10 to 46°CMinus 15 to 24°C
Carrier 42QHG wall units0 to 50°C, or minus 15 to 50°C on low temperature cooling modelsMinus 15 to 24°C
Kaden KSI SeriesMinus 15 to 50°CMinus 15 to 30°C

Carrier’s manual says that outside these ranges, safety protection features may activate and stop the unit. So in a very hot or very cold area, check the range before you choose the size.

Efficiency changes with temperature too

The ACT Government’s buyers guide says a unit’s efficiency varies with the outdoor temperature. It adds that good systems work even when it is minus 10°C in winter. Together with the H2 figure, the range tells you how a unit copes with your coldest days.

Can I get more from the size I choose?

How you use the unit changes how well a given size copes. Actron Air’s LM7-2 and LM24-2 wall controller manual has a section of operating tips that apply to any size.

On hot days

Actron Air suggests starting the air conditioner early in the morning, before the house heats up. It says a unit started in the afternoon, when the home is already very hot, may take a while to cool it. It also suggests keeping curtains and windows closed and stopping draughts at the front and back doors.

On cold days

For a cold day, Actron Air suggests leaving the unit running overnight at a setting 2 to 4°C lower than normal, or starting it a couple of hours earlier than usual. It adds that supplementary heating may help when it is about 7°C or colder outside.

With zones

On a zoned system, Actron Air says turning off zones you are not using, and closing doors to those areas, gives more cooling or heating capacity where you need it. It suggests asking the installer how many zones must stay open.

Ducted systems and insulation

For ducted systems, the ACT guide says ducting should have at least R1.5 insulation. It also notes that ducted systems running through the ceiling reduce the ceiling’s insulation levels. Ask the installer how they will handle both.

The other figures on the label

Mitsubishi Electric’s guide lists two more figures worth checking once you have a size. First, sound levels: the numbers show the sound power of the indoor and outdoor units, and lower numbers mean quieter running. Second, energy usage: the label shows how much energy the unit uses for cooling and heating each year, and Mitsubishi Electric says the lower the figure, the less expensive the unit is to run. Both help when you are choosing between two units of the same capacity.

What should I ask the installer?

Solar Victoria says to take advice from the supplier when they assess your home. These questions follow from the factors above:

  • What floor area and ceiling height have you used?
  • Have you allowed for the room’s orientation, windows, insulation and use?
  • What is the unit’s heating capacity at H2, and is it enough for this room in winter?
  • For a larger home, would ducted or multi head suit better, and is a power upgrade needed?

Leave the installation to licensed trades

Installing a split system means connecting refrigerant pipes and wiring. The Australian Government’s ABLIS service says a refrigerant handling licence is needed for work on air conditioning equipment that could release a fluorocarbon refrigerant. Energy Safe Victoria says unqualified electrical work is extremely dangerous and illegal. The guide to what an air conditioner repair or service visit involves explains what to expect from a licensed technician. If you are replacing an older unit, the guide to when to replace an air conditioner may help.

What is the short version?

Measure the floor area and start with a published guide, such as Solar Victoria’s or Samsung’s. Adjust for orientation, insulation, use and climate. For heating, check the heating capacity, especially the H2 figure measured at 2°C outdoors, because heating output falls as it gets colder. Then compare efficiency stars between units of similar size, and let the installer confirm the size for your home.

Not sure what to do?Call us