Kelvinator Air Conditioner Error Codes, Starting With E1

Reading time 14 minUpdated 28 Nov 2026For Australian homesBy Checked against sources by our review team, 28 Nov 2026
Short answer

A code first guide to Kelvinator air conditioner error codes, from E1 to EC, taken from Kelvinator’s diagnostic and user manuals and labelled by model range. It covers flashing lights, messages that are not faults, the 10 minute reset and the codes that need a licensed technician.

Kelvinator air conditioner error codes appear on the indoor unit’s display, which Kelvinator’s user manuals say shows the self diagnostic codes. This page is built as a quick reference. Find your code in the list, jump to its section, then follow the safe steps.

The meanings come from four Kelvinator documents with Electrolux branding. Two are diagnostic manuals for older KSV ranges. Two are newer user manuals for R32 ranges. Meanings differ between ranges, so each section says which models it covers.

Codes on this page:

  • E1: indoor and outdoor units communication protection
  • E0: EEPROM parameter error, indoor unit
  • E3: indoor fan motor fault
  • E4 and E5: room or evaporator temperature sensors
  • E6: evaporator coil sensors
  • F0: over current error
  • F1, F2 and F3: outdoor sensors
  • F4: EEPROM parameter error, outdoor unit
  • F5, L2 and PA: condenser temperature or outdoor fan feedback
  • P0, P1, P2 and P4: protection codes
  • EC: refrigerant leakage detected
  • FP, FC, D1, D2 and D3: messages that are not faults

What does E1 mean on a Kelvinator air conditioner?

On a Kelvinator air conditioner, E1 means indoor and outdoor units communication protection. In simple terms, the indoor unit has lost contact with the outdoor unit, so the system stops.

Two Kelvinator diagnostic manuals give this meaning. The first is publication KSSSI92 for the KSV26CRB, KSV26HRB, KSV35CRB and KSV35HRB. The second is publication KSSSI90 for the KSV53HRA, KSV62HRA and KSV70HRA. The newer R32 user manuals list E1 as an example of an error code, but they do not give a meaning.

The first step for a Kelvinator E1 error code

For the CRB and HRB models, the diagnostic manual starts with a simple power cycle. Here is that step in owner terms:

  1. Turn off the power to the indoor unit at its isolation switch.
  2. Wait about one minute.
  3. Restore the power.
  4. Run the unit in Auto mode, with the set temperature two degrees above or below the room temperature.

If the Kelvinator air conditioner E1 error clears and stays away, keep an eye on it. If it returns, however, stop there.

Why the next E1 steps are not owner work

After that first step, the manual moves to voltage tests. It checks the supply at the indoor circuit board, at the outdoor terminal block and at two terminals on the outdoor main board. Those tests are on live parts. So they are for a licensed technician or electrician only.

So, as an owner, check only what you can see. Has a circuit breaker tripped? Is the outdoor unit visibly damaged? Then book a licensed technician and tell them the code and the model number.

What do the other Kelvinator error codes mean?

The codes below come mainly from the KSSSI92 diagnostic manual for the KSV26 and KSV35 CRB and HRB models. Its code table is the clearest Kelvinator table found for this page. Where the KSSSI90 manual for the HRA models says something different, the section says so.

Remember the scope. That is, a meaning on this page is only confirmed for the models named in that section.

E0: EEPROM parameter error

On the CRB and HRB models, E0 is an EEPROM parameter error in the indoor unit. The EEPROM is a memory chip that holds the unit’s settings. A fault here is a control board matter, so it needs a technician.

E3: indoor fan motor fault

The KSSSI92 table calls the Kelvinator E3 error code an indoor fan motor circuit error.

In plain terms, the indoor fan is not running as it should. A safe owner check is to make sure nothing is blocking the indoor unit’s air outlet. Never push fingers or objects into the unit. Testing the fan motor and its wiring, however, is technician work.

E4 and E5: room or evaporator sensors

The KSSSI92 table groups E4 and E5 together as an open or short circuit of the room or evaporator temperature sensors. The evaporator is the cold coil inside the indoor unit. These sensors tell the board the room temperature and the coil temperature.

A sensor that is open or shorted gives the board a false reading. So the fix is a sensor check, and possibly a new sensor. On the HRA models, the KSSSI90 table lists E5 against outdoor condenser pipe and compressor temperature sensors instead, which shows why the model matters.

E6: evaporator coil sensors

The Kelvinator E6 error code has a confirmed meaning for the KSV53HRA, KSV62HRA and KSV70HRA. The KSSSI90 manual says it involves the two indoor sensors, the evaporator coil air temperature sensor and the evaporator coil pipe temperature sensor.

The manual’s steps check both sensors’ connections to the indoor main board, then their continuity. If the Kelvinator air conditioner error E6 stays after the sensors are replaced, the indoor main board is replaced. The same page notes that the outdoor LED lights are not affected by this fault. However, no meaning for E6 was found for the CRB, HRB or R32 ranges.

F0: over current error

In the KSSSI92 table, F0 is an over current error. The system has drawn more current than it should. Because the cause sits in the electrical or compressor circuits, F0 is for a technician.

F1, F2 and F3: outdoor sensors

The KSSSI92 table groups these three together. They cover an open or short circuit of the outdoor condenser pipe sensor, the outdoor ambient temperature sensor and the compressor temperature sensor.

However, the table does not pair each code with one sensor. So a Kelvinator AC F1 error code points to one of those outdoor sensors, and a technician finds which. The newer R32 manuals list F1, F2 and F3 as example codes, without meanings.

F4: EEPROM parameter error, outdoor

F4 is the outdoor version of E0. The KSSSI92 table calls it an EEPROM parameter error in the outdoor unit. So it is a board fault for a technician.

F5, L2 and PA: condenser temperature or outdoor fan

The KSSSI92 table groups F5, L2 and PA. It describes them as high and low temperature protection of the condenser, or an outdoor fan motor feedback circuit error. The condenser is the coil in the outdoor unit.

Owners can check one thing here. Make sure the outdoor unit has clear space around it, with no leaves, covers or stored items against it. Kelvinator’s user manuals say not to place obstacles around the air inlets or outlets. But never reach into the outdoor fan.

P0, P1, P2 and P4: protection codes

The KSSSI92 table gives these meanings for the CRB and HRB models:

  • P0: module protection.
  • P1: over voltage or too low voltage protection.
  • P2: temperature protection of the compressor top, with low refrigerant charge named in the table.
  • P4: inverter compressor drive error.

P1 relates to the power supply. Checking supply voltage is electrical work, so leave it to a licensed electrician or technician. P2 links to a low refrigerant charge, which means work on the sealed refrigerant circuit. P0 and P4 involve the inverter drive and compressor. None of these has an owner fix beyond the restart steps below.

EC: refrigerant leakage detected

Both newer Kelvinator user manuals list a refrigerant leakage detection function. When it detects a leak, the indoor unit displays the EC code. One manual covers KSV25CRG to KSD80HRG. The other covers KSV25HWJ to KSD90HWJ.

Those manuals say the refrigerant is odourless, so a leak cannot be detected by smell. If you see EC, switch the unit off and book a licensed technician. Do not keep restarting it, and never try to top up the refrigerant yourself.

Codes listed without a meaning

The R32 user manuals list E2 and P3 as example codes, along with E0, E1, P1, P2, F1, F2 and F3. However, they give no meaning for any of them. For E2 and P3, no Kelvinator meaning was found, so this page gives none. Follow the restart steps once and call a technician if the code returns.

Why is my Kelvinator air conditioner light flashing?

A Kelvinator air conditioner flashing light is not always a fault. The newer user manuals describe a few normal flashes, and one troubleshooting row for lamps that keep flashing.

Normal flashes

The CRG and HRG manual says that when the unit is plugged in and power is available, the OPERATION indicator on the indoor display panel starts flashing. That appears before you choose a mode with the remote, so it is a ready signal.

During heating, both newer manuals say the indoor unit may stop for up to 10 minutes to defrost, and the defrost light blinks. Heating resumes on its own afterwards. Mist may also come out when heating restarts after a defrost.

The display also shows short messages for three seconds when you set Timer ON or Timer OFF, or switch Swing, Turbo or Silence on or off. On the HWJ range, the feature is called Quiet instead of Silence. These are confirmations, not faults.

When lamps keep flashing

Both newer manuals have a troubleshooting row for indicator lamps that continue flashing. It shares a checklist with the error code row:

  • Is there a power failure?
  • Has a switch been turned off, a circuit breaker tripped or a fuse blown?
  • Is the timer operating?
  • Are the remote’s batteries exhausted, or loaded the wrong way round?
  • Are the air filters dirty?
  • Is airflow unrestricted in and out of the indoor and outdoor units?
  • Are the temperature and mode settings correct?

If the lamps still flash after those checks, follow the restart steps below. A symbol on the handset can also cause confusion. The Kelvinator remote symbols guide explains them.

Turning the display off

If the display is just too bright at night, both manuals say the LED button on the remote turns off the indoor unit display. That is a comfort setting, not a fix for a fault.

Which Kelvinator messages are not faults?

Several Kelvinator display codes look like errors but report a feature or normal event. Check these before treating a code as a fault.

FP: 8 degree heating

FP shows when the 8 degree heating function is on. The CRG and HRG manual calls it frost protection, which stops the room dropping below 8°C. Also, it works only in HEAT mode. Pressing ON or OFF, SLEEP, FP, MODE, FAN SPEED, UP or DOWN cancels it.

On the HWJ range, the manual says FP starts when you press the down button twice within one second in heating at a set temperature of 17°C. The unit then runs at 8°C.

FC: forced cooling

The HWJ manual explains FC. Pressing the manual control button twice within 5 seconds starts forced cooling, and FC shows on the display. After about 30 minutes, the unit switches to Auto mode and the display shows 24 instead.

D1, D2 and D3: demand response

On the KSD25HWJ to KSD90HWJ models, the HWJ manual says D1, D2 or D3 is normal operation of the DRED function. That function is started by your power provider to reduce demand on the power grid. The manual says to contact your power provider for details.

Other normal events

  • A delay after a restart. The compressor does not run for about 3 minutes after the power is suddenly switched off and on. This protects the compressor.
  • Fan speed changing from off, to very slow, to normal in heating. This stops cold air blowing at start up, and also happens during defrosting and low temperature heating.
  • Hissing during or just after operation, which is refrigerant flowing.
  • Squeaking from plastic and metal parts expanding and contracting.

How do I reset a Kelvinator air conditioner after an error code?

Both newer Kelvinator user manuals give the same basic routine. They note first that the unit may stop operation, or keep running in a safety condition, depending on the model.

  1. Wait about 10 minutes. The fault may clear on its own.
  2. If it does not, switch the power to the air conditioner off and then on again.
  3. If the problem still exists, switch off the power and contact the nearest customer service centre.

Allow for the 3 minute compressor delay after the power comes back. When you contact service, both manuals say to describe the malfunction in detail and give the model number. For the CRB and HRB models with E1, the one minute power off described in the E1 section is the diagnostic manual’s own first step.

Use the remote for everyday on and off

The power cycle is a reset step only. Kelvinator’s safety pages say not to operate or stop the unit by switching it on or off at the power source, because of heat build up. So use the remote for normal use.

Other restart behaviour

Kelvinator’s newer units have auto restart. After a blackout, the unit stops once, then restarts and returns to its previous operation when power comes back. If operation is erratic or unresponsive, the HWJ manual says interference from mobile phone towers and remote boosters can be the cause. Disconnect the power, reconnect it, then press ON and OFF on the remote.

For symptoms without a code, such as weak cooling or noise, see the Kelvinator air conditioner troubleshooting guide.

Which Kelvinator codes need a licensed technician?

Kelvinator’s safety pages say to disconnect the power if strange sounds, smells or smoke come from the unit. They also say not to open the unit during operation, and not to disassemble or modify it. If water enters the unit, turn it off, disconnect the power and contact a qualified service technician.

Codes to leave to a technician

  • EC, the refrigerant leak warning.
  • P2, because the table links it to a low refrigerant charge.
  • P0, P4 and F0, which involve the inverter drive, compressor or current.
  • E0 and F4, which are memory chip faults on the boards.
  • Any code that returns after the 10 minute wait and one power cycle.

The refrigerant rule

The CRG and HRG manual says the unit uses R32, a mildly flammable gas, class 2.2 under AS 1677. It must be handled by a refrigeration mechanic with an appropriate Australian refrigerant handling licence. The Australian Government’s ABLIS service confirms that this licence is needed for work on air conditioning equipment that could release a fluorocarbon refrigerant. The Australian Refrigeration Council issues it.

The electrical rule

Energy Safe Victoria says unqualified electrical work is extremely dangerous and illegal, and to always hire a licensed electrician. Other states also have their own regulators with similar rules. So never open the indoor unit’s electrical cover or the outdoor unit. The air conditioning repair guide explains what to have ready for the visit.

Where can I get the Kelvinator error code list PDF?

Where to find a Kelvinator AC error code list PDF depends on the document type. Kelvinator’s user manuals only list example codes. The diagnostic manuals carry the full table, but they are written for service technicians.

The documents behind this page

  • Kelvinator diagnostic manual, publication KSSSI92, for KSV26CRB, KSV26HRB, KSV35CRB and KSV35HRB.
  • Kelvinator diagnostic manual, publication KSSSI90, for KSV53HRA, KSV62HRA and KSV70HRA.
  • Kelvinator Inverter Air Conditioner User Manual, part number 66129913264, for KSV25CRG to KSD80HRG.
  • Kelvinator Inverter Air Conditioner User Manual for KSV25HWJ to KSD90HWJ.

All four carry Electrolux branding. The two user manuals name Electrolux Home Products Pty Ltd and say Kelvinator is part of the Electrolux family. Kelvinator’s website has a user manual page. Look there for the same title and part number.

Match the document to your model

Each user manual has a box to record the model and serial number, and lists its models on the cover. If the cover does not list your model, the codes may differ. The Kelvinator owner guide covers the ranges and general care.

Keep up the basic care

Both newer user manuals say to clean the filters every 3 months, or as required. A routine service lets a technician check the parts owners cannot reach. The guide to how often to service an air conditioner covers the timing.

What is the short version for Kelvinator codes?

On the CRB, HRB and HRA diagnostic manuals, E1 means the indoor and outdoor units have lost communication. E3 is an indoor fan fault. E6, on the HRA models, is an evaporator sensor fault. F1, F2 and F3 point to outdoor sensors on the CRB and HRB models. EC means a refrigerant leak has been detected. FP, FC and D1 to D3 are features, not faults.

Wait 10 minutes, then power cycle once. If the code returns, or if you see EC, switch off and book a licensed technician.