A Braemar SpectroLINK controller guide from Seeley International’s own manual: a legend of every display symbol including DOOR and the battery, then setting the time and day, programming WAKE, AWAY, HOME and SLEEP, using the Home and Away button and zones.
The Braemar SpectroLINK controller is the wall control for Braemar 3 Star, 4 Star and 5 Star gas ducted heaters, and it can also run an evaporative cooler or add on refrigerated cooling. Its screen packs a lot into a small space, and several buttons sit behind a front door. This page starts with a legend of everything the display can show. Then it walks through four set up tasks in order: date and time, the four daily program periods, Home and Away, and zones.
Every step comes from Seeley International’s Spectrolink Comfort Controller Home Owner’s Manual, part number 623528, which covers Braemar 3 Star, 4 Star and 5 Star gas ducted heaters. If your controller is a MagIQtouch touchscreen instead, see the guide to programming a Braemar MagIQtouch heater.
What do the symbols on a Braemar SpectroLINK display mean?
The manual lists every segment the display can show. Some appear only with the door open, and some only on heaters with zones.
Mode and status words
| Display | What the manual says it means |
|---|---|
| HEAT | The controller is set to run the heater |
| COOL | The controller is set to run cooling |
| MAN | Manual mode |
| AUTO | The automatic program is running |
| ON | The heater is on. It flashes at start up and stays steady once gas is burning |
| OFF | The heater is off |
| WAIT | Flashes with ON at the start of a heating cycle, or alone at the start of a cooling cycle |
| SET | Flashes with another segment, such as the time, to show that setting is waiting to be set |
| RESET | Flashes if a fault occurs |
Symbols
- Flame: heat mode is selected and gas is burning. A full flame means high gas, a small flame means low gas.
- Snowflake: in evaporative cooling, the pump is on. In refrigerated cooling, cooling is on.
- Fan: the fan symbol turns, and in heat mode the fan speed number shows next to it.
- Spanner: the heater needs attention from a Braemar service technician.
- Battery: the power supply to the heater is off. More on this below.
The temperature number
The same number means two things. With the door closed, it shows the room temperature. With the door open, it shows the set or programmed temperature. So if the figure jumps when you open the door, nothing is wrong.
Period words
WAKE, AWAY, HOME and SLEEP show which of the four program periods is running. They are explained in the programming section.
The DOOR and battery symbols
First, DOOR flashes when the controller’s front door has been open for more than 30 seconds. It is a reminder, not a fault. Pressing any button clears it. The manual also points out that the heater will not turn off just because the door is open, so close it when you finish.
The battery symbol, however, is different. It shows when the power supply to the heater is off. The manual says the controller holds its current settings for up to one hour, and keeps the program indefinitely. So after a short power cut you may only need to check the clock. After a longer one, the time and day need setting again, as the next section explains.
How do I set the date and time on a Braemar heater?
Note that the SpectroLINK stores the day of the week and the time. There is no calendar date to set. The manual describes two cases.
After the power has been off
When power returns to the heater, the display flashes SET and 12:00 pm. That is the controller asking for the time. Follow these steps:
- Open the front door of the controller.
- Use the UP and DOWN buttons to set the time. Hold a button down for faster adjustment.
- Press SET. The display now shows SET with the day flashing.
- Use UP and DOWN to choose the current day.
- Press SET.
- Close the door.
When the clock is simply wrong
If the time is out, you can adjust it without a power cut:
- Turn the controller OFF.
- Open the door and hold SET for 3 seconds.
- Set the time with UP and DOWN, then press SET.
- Set the day with UP and DOWN, then press SET.
Why the time matters
This matters because the automatic program runs by the clock. The manual’s troubleshooting list includes a heater that comes on at the wrong time. Its first check is whether the time is set to AM or PM correctly.
How do I turn the heater on from a SpectroLINK?
The manual’s start up steps are simple, and they explain what the display shows while the heater lights.
- Make sure the gas and the power at the heater are turned on.
- Open the door and press AC MODE until HEAT shows.
- Close the door and press ON and OFF.
- The heater restarts in the mode it was last turned off in.
- In MAN, press UP until the temperature you want shows. In AUTO, the heater follows the program.
What the display does as the heater starts
First, in AUTO standby, the heater waits for the room to fall below the set temperature. Next, when it calls for heat, ON and WAIT flash while the heater starts up. Then, once gas is burning, WAIT and the flame flash during a short pre fan period. Finally, the fan symbol and speed appear for normal running. None of these flashing stages is a fault.
If you also have a cooler
This Braemar controller can switch to an evaporative cooler with AC MODE. The cooling half of the manual says the HOME and AWAY, RESET, FAN and zone buttons are not used for evaporative cooler operation. So the steps on this page apply to heating.
What does WAIT mean on a Braemar evaporative cooler controller?
The cooling half of the manual has its own short set of steps. First, make sure the water and power at the cooler are on. Next, open the door and press AC MODE so the controller is in COOL mode. Then close the door and press ON and OFF.
- In Manual mode, press UP until the fan speed you want shows. If the cooler has been off for more than 10 minutes, WAIT and the fan speed flash. The manual says this is the filter pad pre wet cycle, which takes 2 minutes.
- The AUTO and MANUAL button, behind the door, switches between the two modes. In Automatic mode, the controller sets the pump and fan speed from the temperature it senses. UP or DOWN overrides that level until the cooler is turned off and restarted.
- In Manual mode, the COOL and VENT button turns the pump on for cooled air, or off for ventilation only.
How do I program a Braemar SpectroLINK?
The SpectroLINK has a built in AUTO program. It turns the heater on and off several times a day, at different temperatures, and can heat different zones in each period. You can change any time, temperature, zone or fan speed.
The four periods and their default settings
Each day has four periods, in this order: WAKE, AWAY, HOME and SLEEP. The manual’s default heating program is:
| Period | Starts | Temperature | Zones | Fan |
|---|---|---|---|---|
| WAKE | 6:00 | 20°C | 1, 2, 3, 4 | 10 |
| AWAY | 8:30 | 14°C | 1, 2, 3, 4 | 10 |
| HOME | 5:00 | 21°C | 1, 2, 3, 4 | 10 |
| SLEEP | 10:30 | 14°C | 1, 2, 3, 4 | 10 |
The manual’s display section describes typical times too. WAKE is usually 6.00 am to 8.30 am at 18 to 22 degrees. SLEEP is usually 10.30 pm to 6.00 am at 12 to 16 degrees. The manual includes a blank column beside the defaults to record your own settings.
Starting the program change
- Make sure the controller is in standby mode.
- Open the door and press AC MODE to choose the heat program.
- Press SET to enter program setting.
- Use UP and DOWN to choose one day, or a group of days such as Monday to Friday.
- Press SET to accept the days.
Setting each period
Each period follows the same sequence: time, then temperature, then zones, then fan speed. For WAKE:
- With SET and the time flashing, use UP and DOWN to choose the start time. Press SET.
- With SET and the temperature flashing, choose the temperature. Press SET.
- If your system has zones, SET and ZONE flash. Press a zone button to turn heating off to that zone, then press SET.
- With SET and FAN flashing, use UP and DOWN to adjust the amount of heating to the zones. Press SET.
After that, repeat the same steps for AWAY, HOME and SLEEP. If the system has no zones, the zone step does not appear.
Leaving and checking the program
Also, you can leave program setting at any time by pressing RESET. The manual says any changes made so far are saved. To run the program, close the door, turn the controller on and choose AUTO with the AUTO and MANUAL button.
If the heater still starts when it should not, the manual’s checks are the AM and PM setting, HEAT mode rather than COOL, the set temperature and the programmed on times. The Braemar ducted heating troubleshooting guide covers that problem in more detail.
Changing the temperature for now only
In AUTO, pressing UP or DOWN with the door closed changes the temperature only until the next period starts. Then it goes back to the programmed value. In MAN, an override becomes the new default temperature.
What does the Home and Away button do?
The HOME and AWAY button sits on the front, usable with the door closed. The manual says to use it when your day does not follow the schedule.
In AUTO mode
Pressing the button brings the next scheduled period forward. The manual gives two examples:
- Your HOME period starts at 5:00 pm, but you get home at 4:30 pm. Press HOME and AWAY, and the Home settings start straight away.
- Your AWAY period starts at 9:00 am, but you leave at 8:00 am. Press it, and the Away settings start early.
Normally the display shows AWAY during the day and HOME in the evening. The manual gives typical times of 8.30 am to 5.00 pm for AWAY and 5.00 pm to 10.30 pm for HOME.
In MAN mode
In Manual mode, the heater runs to either the Home or the Away settings. Pressing the button while it runs switches between them. The default Home and Away settings come from the AUTO program.
The other front buttons
With the door closed you also have ON and OFF, and UP and DOWN for a temporary temperature change. Behind the door are RESET, AUTO and MANUAL, SET, AC MODE, the setting UP and DOWN buttons, a FAN button to override the fan speed, COOL and VENT for an evaporative cooler pump, and the zone buttons. The manual notes the FAN and zone buttons apply to 4 Star and 5 Star heaters only.
How do zones work on Braemar ducted heating?
The manual says Braemar 4 Star and 5 Star heaters can be zoned. Zoning lets you heat individual areas of the home. A system can have up to 4 zones. Zones are not available on 3 Star heaters.
Reading the zone display
When zones are installed and set, the display shows the word ZONE with the numbers 1 to 4. A number on the screen means that zone is active. A system installed with one zone shows ZONE and 1. Zones do not appear at all unless the installer has set them.
Turning zones on and off
For an immediate change, open the door and press a zone button to turn heating to that zone on or off. Zones also work in refrigerated cooling mode, where the system has it. To change which zones heat in each period, set them in the program steps above.
Keep enough outlets open
Even so, zoning has a limit. The manual’s troubleshooting list says that if the home is not heating well, check there are enough outlets open for the fan speed selected. It suggests opening more outlets or another zone. For how zoning works in general, see the guide to how ducted heating zones work.
What should I do if RESET or the spanner appears?
The manual’s troubleshooting steps for RESET are short. If RESET flashes with a number shown in place of the time, open the door and press RESET. The heater should run after about 20 seconds. If RESET comes back, wait 10 minutes and press RESET again. If the heater still fails to start, contact your service agent.
Before you press anything, write the number down. The Braemar fault codes guide explains what those numbers mean. When the spanner shows, the manual says to call a service agent to look at the heater.
Gas side work is not owner work
The manual says installation is not owner work, and not to run the heater with panels, covers or guards removed. It recommends maintenance at the start of each heating season by a person trained in Braemar heaters. Energy Safe Victoria also recommends that gas heaters are serviced at least every two years by a qualified gasfitter. Each state has its own gas regulator. The ducted heating service page explains what a heater service covers.
Filter care
The manual’s maintenance note says to clean filters every 2 weeks and replace them annually. Its troubleshooting list also asks whether the return air filter is blocked when the home is not heating well.
Where is the Braemar SpectroLINK manual?
The Braemar SpectroLINK controller manual, titled the Spectrolink Comfort Controller Home Owner’s Manual, is on Seeley International’s website, in its product manuals section. The edition used here is the 2007 heating and cooling manual, part number 623528. Check that the cover names your heater range before you rely on it.
Before calling for service, the manual asks you to note the heater’s model, model number and serial number. It says a data label on the end of the heater shows the model number. For the Braemar range as a whole, see the Braemar heating and cooling owner guide.
What is the short version for the Braemar SpectroLINK?
The display tells you more than it seems. A flashing DOOR means the door is open, the battery means power is off, and the temperature number changes meaning when you open the door. Set the time and day first, with the right AM or PM. Then adjust the four daily periods, WAKE, AWAY, HOME and SLEEP, each with its own time, temperature, zones and fan speed.
Use HOME and AWAY to bring a period forward on an unusual day. On 4 Star and 5 Star heaters, use the zone buttons, but keep enough outlets open. If RESET or the spanner appears, follow the manual’s steps once, then leave the heater to a service agent.