You asked
We'll solve it.Opening your answer
Ducted heating · Brivis · Error & Fault Codes

Brivis error code 56, the pressure switch lockout explained

Reading time 5 minUpdated 14 Nov 2026For Australian homesBy Checked 4 Nov 2026
Short answer

Brivis error code 56 means the heater has locked out on its pressure switch. Brivis says this is usually too much restriction in the flue pipe or, on SP6 models, the condensate drain, and gusty wind blowing back down the flue can also trip it. Check the flue terminal and condensate pipe for blockages from a safe distance, reset once, then call a technician.

It is a windy winter night, the heater stopped, and the Networker shows a spanner. The message says Brivis error code 56. You are wondering whether the weather has something to do with it.

It might. According to the Brivis Ducted Gas Heater Operation Manual, code 56 means a lockout has occurred on the pressure switch, usually caused by too much restriction on the flue pipe, or the condensate drain on SP6 models. The Brivis error code sheet adds that gusty wind can cause the pressure switch to open, because air blows back down the flue.

This guide explains what the pressure switch does, the owner checks Brivis lists, and when to call a licensed gas fitter.

What does Brivis error code 56 mean?

A gas heater must move its combustion gases safely out through the flue. The pressure switch is one of the ways the heater confirms this is happening. If the switch does not see the right conditions, the heater locks out and shows code 56.

Brivis points to three causes that owners can understand.

  • A blockage or restriction in the flue pipe.
  • A blocked condensate drain, on SP6 models.
  • Gusty wind blowing air back down the flue.

Why SP6 models have a condensate pipe

SP6 heaters produce condensate as they run. Brivis says this can be about 2 to 3 litres per hour under continuous running, depending on the size of the heater. That water drains away through a condensate tube. If the tube blocks, Brivis says it will seriously affect performance and may shut the heater down.

Safe checks Brivis lists for code 56

You can look at these from outside without opening anything. Do not touch the flue while the heater is running, as Brivis warns it can become very hot.

  1. Look at the flue terminal. On external heaters, check it is in place and clear of leaves, plant growth or other obstructions.
  2. Check the air intake. Brivis says the air intake at the burner end of the heater roof panel should be clear of leaves.
  3. Check the condensate pipe (SP6). Look along the visible pipe for kinks, crushing or a blocked outlet, and check there is no water pooling around the heater.
  4. Think about the weather. If it is very gusty, the code may be caused by wind down the flue rather than a fault.

What not to do

  • Do not hose the flue terminal. Brivis lists this as a caution.
  • Do not remove the flue, cowl or any heater panels.
  • Do not poke anything down the flue.
  • Do not pull apart condensate fittings that connect to the heater.

Should you reset after code 56?

Yes, once, after you have looked over the flue, intake and condensate pipe, because a wind gust can trip the pressure switch without anything being wrong. Jot down the code and date, then use the steps in our guide to resetting a Brivis heater.

If the code followed a gusty spell and the heater now runs normally, wind was the likely cause. If it comes back on a calm day, a blockage is more likely.

Is vapour from the flue a sign of code 56?

Not on its own. Brivis treats a plume of vapour from a running ducted heater as normal, and warns the terminal itself can be hot. Vapour with the heater running normally is expected. Code 56 is about the heater sensing a restriction, so look for leaves, plant growth or other obstructions around the terminal rather than the vapour itself.

When code 56 is a job for a gas fitter

  • Code 56 returns after a reset on a calm day.
  • You can see a blockage in the flue or terminal that you cannot safely clear by hand from the outside.
  • The condensate pipe looks damaged, or water is pooling around the heater.
  • The flue terminal is damaged or missing.
  • Code 56 keeps appearing every windy day.

The flue system and pressure switch are part of the gas installation. Testing either one belongs with a licensed gas fitter or a Brivis-authorised technician.

Booking goes faster with the details Brivis asks for: the message on screen, your model and the appliance type. Mention too whether each code 56 lined up with windy weather or appeared on still days, as that helps separate gusts from a genuine blockage.

Related answers

Your code 56 questions answered

Can wind cause Brivis error code 56?

Yes. The Brivis error code sheet says gusty wind can cause the pressure switch to open as air blows back down the flue.

Does code 56 only happen on SP6 heaters?

No. Any listed model can show it for a flue restriction. The condensate drain cause applies to SP6 models only.

Can I clean the flue myself?

You can remove loose leaves from around an external flue terminal if it is cool and within easy reach. Anything inside the flue is for a licensed gas fitter.

Is error 56 a gas leak?

Brivis describes it as a pressure switch lockout, not a gas leak. A gas smell is a different emergency: clear out of the area and phone the gas emergency number.

Brivis error code 56: the key points

Brivis error code 56 is a pressure switch lockout. Brivis links it to flue restrictions, a blocked condensate drain on SP6 models, and gusty wind down the flue.

Look, do not touch. Check the flue terminal, air intake and condensate pipe from outside, reset once, and call a gas fitter if it returns.

For other numbers, see our Brivis heater error codes guide and the wider Brivis ducted heating troubleshooting checklist.

Not sure what to do?Call us