Find your Daikin error code in a quick table grouped by system type, with the meaning from Daikin’s own manuals and its global code list. Each code shows what an owner can safely check and when to stop and call a licensed technician.
Daikin error codes are two character signals that a Daikin air conditioner stores when it stops itself to protect its parts. If your remote or wired controller is showing one right now, start with the quick find table below. It gives the meaning Daikin prints in its own manuals, the type of system the code belongs to and a plain action level.
The action levels work like this. “Check first” means there is a safe owner check, such as clearing airflow or cleaning filters as the manual’s care section describes. “One reset, then stop” means a single power restart is reasonable, and a code that comes back points to a real fault. “Technician only” means you leave the system off and book a licensed technician.
Every meaning here comes from Daikin’s Australian wall split operation manuals. For a few codes those manuals do not cover, it comes from Daikin’s global self-diagnosis document. Wording changes a little between model families, so treat this page as a guide and confirm the code against the manual for your own unit.
| Code | System type | Daikin’s short meaning | Action level |
|---|---|---|---|
| UA | Split | Indoor and outdoor unit combination fault | Technician only |
| U0 | Split | Refrigerant shortage | Technician only |
| U2 | Split | Drop voltage or main circuit overvoltage | One reset, then stop |
| U4 | Split | Failure of transmission between indoor and outdoor unit | One reset, then stop |
| A1 | Split | Indoor circuit board (PCB) defect | One reset, then stop |
| A3 | Not in split manuals, global list | Drain level control system abnormality | Technician only |
| A5 | Split | High pressure control or freeze-up protector | Check first |
| A6 | Split | Fan motor fault | One reset, then stop |
| C4 | Split | Faulty heat exchanger temperature sensor | One reset, then stop |
| C7 | Split, Zena | Front panel open and close fault | Check first |
| C9 | Split | Faulty suction air temperature sensor | One reset, then stop |
| CC | Split | Faulty humidity sensor | One reset, then stop |
| EA | Split | Cooling and heating switching error | Technician only |
| E1 | Split | Circuit board fault | One reset, then stop |
| E3 | Not in split manuals, global list | Actuation of the high pressure switch | Check first |
| E5 | Split | OL started (compressor overload) | One reset, then stop |
| E6 | Split | Faulty compressor start up | Technician only |
| E7 | Split | DC fan motor fault | Check first |
| E8 | Split | Overcurrent input | One reset, then stop |
| F3 | Split | High temperature discharge pipe control | One reset, then stop |
| F6 | Split | High pressure control in cooling | Check first |
| F8 | Split | Operation halt due to compressor internal temperature | Technician only |
| H0 | Split | Sensor fault | One reset, then stop |
| H6 | Split | Operation halt due to faulty position detection sensor | One reset, then stop |
| H8 | Split | DC current sensor fault | One reset, then stop |
| H9 | Split | Faulty outdoor air temperature sensor | One reset, then stop |
| J3 | Split | Faulty discharge pipe temperature sensor | One reset, then stop |
| J6 | Split | Faulty outdoor heat exchanger temperature sensor | One reset, then stop |
| J8 | Split | Faulty liquid pipe temperature sensor | One reset, then stop |
| L3 | Split | Electrical parts heat fault | Check first |
| L4 | Split | High temperature at inverter circuit heatsink | Check first |
| L5 | Split | Output overcurrent | One reset, then stop |
| P4 | Split | Faulty inverter circuit heatsink temperature sensor | One reset, then stop |
What do Daikin error codes mean?
A Daikin code is a letter followed by a digit or a second letter. The Alira X, FTXF and Cora operation manuals print one table that starts with 00, which simply means normal. Like the newer Zena manual (booklet 3P705032-1), they sort the codes into three groups: system codes, indoor unit codes and outdoor unit codes.
In practice, the U codes sit in the system group and cover power, refrigerant charge and the link between the two units. The A and C codes belong to the indoor unit. The E, F, H, J, L and P codes come from the outdoor unit, where the compressor, its inverter drive and its sensors live.
So the letter tells you where the system found the problem. It does not tell you which part has failed. A sensor code, for example, can mean a faulty sensor, a loose connector or a board fault, and only testing separates them.
Meanings also drift a little between families. The older Zena manual (booklet 3P369488-1) calls A5 “freeze-up protection or heating peak-cut control”, while the Alira X manual calls it “high pressure control or freeze-up protector”. The idea is the same, yet the wording differs, which is one reason to keep your own manual handy.
Why the operation lamp blinks
On Daikin wall splits, a blinking OPERATION lamp is the first sign that a code is stored. The Alira X manual pairs it with one breaker restart, which the reset section below explains. If the lamp still blinks after that, the manual says to check the error code and consult your dealer.
For other lamp signals and symptoms that come without a code, see Daikin troubleshooting by symptom.
How do I check the error code on my Daikin remote?
The steps depend on whether you have a wireless remote or a wired wall controller. Only follow steps from the manual for your own remote, because button layouts differ between models.
Wireless remotes on Australian wall splits
The Alira X (remote ARC466A98), FTXF (ARC480A100) and Cora (ARC466A80) manuals each include a section called “Fault diagnosis by remote controller”. The steps in those manuals run like this:
- Hold down the button pictured in that section of your manual for about 5 seconds. A code starts blinking in the temperature display.
- Press the same button again and again. Each press shows a new code.
- Stop when the indoor unit gives a long beep. The code on the screen at that moment is the stored fault.
- A short beep, or two quick beeps, means the code on screen does not match the fault, so keep pressing.
- To leave the check, hold the button for about 5 seconds again. The display also clears by itself if you press nothing for 1 minute.
The Australian manuals show the button as a picture rather than a name. Daikin Malaysia’s official error code page names it as the ON TIMER CANCEL or OFF TIMER CANCEL button, and the Alira X remote has a TIMER CANCEL button. Even so, match the button to the picture in your own manual before you start.
First, write the code down straight away. Then note the model number from the label on each unit. Daikin Australia’s model number guide says the label sits on the right or bottom edge of a wall split. On the outdoor unit, it is on the side or back.
Wired controllers on ducted systems
Daikin Australia’s ducted zone controller manual for the BRC24Z4 and BRC230Z4 controllers (booklet 3P209820-1) covers zones and timers but contains no error code table. For wired controllers, Daikin’s operation manual for the BRC1E73 wired remote controller, a North American model, shows how this style of controller reports a fault.
According to that manual, an error makes the basic screen flash “Error: Push Menu button” and the operation lamp flashes. A warning shows “Warning: Push Menu button” instead, and the lamp does not flash. Pressing the Menu button then makes the code flash, sometimes with a service contact and model name. Your own controller may differ, so check its manual first.
Daikin split system error codes
This group follows the table in Daikin’s operation manual for the Alira X range (FTXM20AVMA to FTXM71AVMA, booklet 3P827114-1). The FTXF and Cora manuals carry the same list, although the FTXF table leaves out J8. C7 comes from the older Zena manual (FTXJ25PVMAW to FTXJ50PVMAS).
For causes, each section also draws on Daikin’s global “Simple Self-Diagnosis by Malfunction Code” document (SM-TS3), which lists the likely causes a technician tests. None of those causes is an owner repair, and they appear here only so you know what the code is pointing at.
Multi split systems do not get a separate group here. None of the Daikin Australia manuals listed above prints a separate multi split table. Instead, read the code on the indoor unit that shows it and use that unit’s manual.
U4 is part of this table too. It has a short section further down, together with L5.
What does Daikin UA mean?
Daikin’s meaning: The Alira X manual lists UA as an indoor and outdoor unit combination fault. In other words, the two units do not suit each other, or the system thinks they do not.
Safe to check: Think back to any recent work. The global SM-TS3 document lists wrong model connections, an excess of connected indoor units, a refrigerant type mismatch and a missed board setting after a part swap. A new install or a recent repair is therefore a useful clue to pass on.
Stop and call: Leave the system off. Matching units and board settings are installer work.
What does Daikin U0 mean?
Daikin’s meaning: U0 is listed as refrigerant shortage. The control board has judged, from its sensor readings, that the charge looks too low.
Safe to check: Very little. You can note whether cooling or heating had been getting weaker over recent weeks, because that history helps the technician. The global list also names a faulty thermistor, a faulty low pressure sensor and a board fault as possible causes, so the code is not proof of a leak.
Stop and call: Straight away. A refrigerant circuit is sealed, and Australian law requires a licence for work that could release refrigerant. Never try to add gas.
What does Daikin U2 mean?
Daikin’s meaning: The Daikin U2 error code means drop voltage or main circuit overvoltage. The older Zena manual calls it over-voltage detection. In each case, the unit saw supply voltage it did not like.
Safe to check: Ask whether the power dipped, flickered or went out. The Alira X manual explains that, with the OPERATION lamp still on, the unit may stop after sudden large voltage swings and resume by itself in about 3 minutes. If the lamp is blinking instead, one restart at the circuit breaker is reasonable.
Stop and call: If U2 returns on a normal day, or other appliances also misbehave, the supply or wiring needs a licensed electrician or technician.
What does Daikin A1 mean?
Daikin’s meaning: A1 is listed as indoor PCB defectiveness, which is a fault with the indoor unit’s main circuit board.
Safe to check: The global SM-TS3 list gives “external factor (noise etc.)” as one cause besides a faulty board. Electrical noise or a storm can upset a board without damaging it. A single breaker restart, done once, tests for that.
Stop and call: If A1 comes back after the restart, treat it as a board fault. Circuit boards sit behind covers that only a technician should remove.
What does Daikin A5 mean?
Daikin’s meaning: The Alira X manual lists the Daikin A5 error code as high pressure control or freeze-up protector. In cooling, the indoor coil has run too cold. In heating, the global list calls it high pressure control, because the indoor coil has run too hot.
Safe to check: Airflow first. The SM-TS3 list names a clogged indoor air filter as a cause. With the breaker off, clean the filters as the manual describes, which means vacuuming or washing them, drying them in the shade and refitting them. Then make sure nothing blocks the indoor or outdoor unit.
Stop and call: If clean filters and clear airflow do not stop A5, the coil sensor or the system needs testing. A coil that has iced over should also be left for a technician.
What does Daikin A6 mean?
Daikin’s meaning: A6 is a fan motor fault in the indoor unit. The board asked the fan to run and did not get the response it expected.
Safe to check: Daikin’s global list puts broken wires, a disconnected fan motor connector, a faulty motor and a faulty indoor board behind this code. None of these is an owner check. What you can do is a single power restart, with nothing pushed into the air outlet.
Stop and call: Never put fingers or tools into the outlet, which the Alira X manual warns against because of the high speed fan blades. A returning A6 needs a technician.
What does Daikin C4 mean?
Daikin’s meaning: C4 means a faulty heat exchanger temperature sensor on the indoor side. That sensor tells the board how cold or hot the indoor coil is running.
Safe to check: Nothing inside the unit. The global list gives a faulty thermistor, a faulty indoor board and a poor connector contact. After that, restart once to see whether the reading recovers.
Stop and call: A sensor that keeps reporting a fault needs a meter test, so a repeat C4 goes to a technician.
What does Daikin C7 mean?
Daikin’s meaning: The older Zena manual (booklet 3P369488-1) lists C7 as a front panel open and close fault. Zena models have a motorised front panel that opens when the unit starts.
Safe to check: The newer Zena manual says that if the front panel does not open, check for obstacles and try opening it with the remote. Clear anything in the panel’s path, such as curtains or items placed on top.
Stop and call: Do not force the panel by hand. If the path is clear and C7 returns, the panel motor or limit switch needs a technician.
What does Daikin C9 mean?
Daikin’s meaning: The Alira X table calls C9 a faulty suction air temperature sensor, which the older Zena manual names the room temperature thermistor. This is the sensor that reads the air coming back into the indoor unit.
Safe to check: The Alira X manual advises against placing objects around the indoor unit, so clear the space near it. After that, a single restart is the only owner step.
Stop and call: The global list points to the thermistor, its connector or the indoor board. A repeat C9 means one of those needs testing.
What does Daikin CC mean?
Daikin’s meaning: CC is a faulty humidity sensor. It appears in the Alira X, FTXF and Cora tables.
Safe to check: First, restart once with the breaker. If the unit then runs normally, keep an eye on it over the next few days.
Stop and call: Daikin’s global list gives the sensor itself or its connector as the cause, so a returning CC is a parts job.
What does Daikin EA mean?
Daikin’s meaning: EA is listed as a cooling and heating switching error. The older Zena manual calls it a four way valve abnormality. That valve reverses the refrigerant flow when you change between cooling and heating.
Safe to check: Note which mode you were using and whether the room had stopped cooling or heating before the code appeared. The global list includes a faulty valve, a shortage of gas, a faulty thermistor and an outdoor board fault.
Stop and call: Because the valve sits inside the sealed refrigerant circuit, this is technician work from the start.
What does Daikin E1 mean?
Daikin’s meaning: E1 is a circuit board fault, listed in the outdoor group. The older Zena manual words it as an outdoor unit PCB abnormality.
Safe to check: The global list adds a poor connection in the wires between the indoor and outdoor units. The Alira X manual asks owners to check the outdoor unit’s stand and mounts for damage after long use, which you can do by eye without opening anything. Then restart once.
Stop and call: A board or wiring fault inside the outdoor unit is electrical work. If E1 returns, a licensed technician should test it.
What does Daikin E5 mean?
Daikin’s meaning: The Alira X table prints E5 as “OL started”. The older Zena manual explains this as OL activation, compressor overload. The compressor’s overload protection has tripped.
Safe to check: Clear the area around the outdoor unit so it can breathe, with the breaker off. Then allow one restart. The global list gives causes such as a locked compressor, high differential pressure and an inverter board fault, none of which an owner can test.
Stop and call: After a second E5, leave the system off. The newer Zena manual says the cause should be understood before a code is reset again.
What does Daikin E6 mean?
Daikin’s meaning: E6 is faulty compressor start up. The older Zena manual calls it compressor lock.
Safe to check: Nothing, apart from noting what you heard. A hum followed by silence from the outdoor unit is worth describing to the technician.
Stop and call: Now. The global SM-TS3 list names a faulty compressor, a control board fault and a stop valve that was not opened. Each needs a technician with gauges and meters.
What does Daikin E7 mean?
Daikin’s meaning: The Alira X manual lists the Daikin E7 error code as a DC fan motor fault, and the older Zena manual calls it DC fan lock. This is the large fan in the outdoor unit.
Safe to check: Daikin’s global list includes a fan that cannot turn because something is caught in it. With the circuit breaker off, look at the outdoor fan grille from a safe distance for sticks, leaves or a plastic bag. Remove only loose debris outside the grille.
Stop and call: Never reach through the grille. If nothing is caught and E7 returns, the motor, its harness or the board needs a technician.
What does Daikin E8 mean?
Daikin’s meaning: E8 means overcurrent input. The unit drew more current from the supply than it should.
Safe to check: Check whether the breaker has tripped as well. If it has not, one restart is reasonable. If it has, call your dealer or a licensed technician. The Alira X manual lists a breaker that cuts off the operation frequently as a reason to call your dealer immediately.
Stop and call: The global list links overcurrent of the inverter compressor to a faulty compressor, a faulty main circuit capacitor or a power transistor fault. Those parts sit inside the outdoor unit’s electrical section, so a returning E8 is strictly for a technician.
What does Daikin F3 mean?
Daikin’s meaning: The Daikin F3 error code means high temperature discharge pipe control. The discharge pipe carries hot gas out of the compressor, and the system stopped because that pipe was reading too hot.
Safe to check: Make sure the outdoor unit has clear space and is not boxed in. After that, one breaker restart is the only owner step.
Stop and call: The global SM-TS3 list gives a faulty discharge pipe thermistor, a genuinely abnormal discharge temperature, a board fault or a poor connector contact. A technician needs to measure which one it is.
What does Daikin F6 mean?
Daikin’s meaning: F6 is high pressure control in cooling. The outdoor side has run at a pressure the system treats as unsafe.
Safe to check: The Alira X troubleshooting table tells owners to check for anything blocking the air inlet or outlet when the unit suddenly stops with a blinking lamp. Turn off the breaker, clear the obstruction, then restart.
Stop and call: The global list adds an overcharge of refrigerant and disconnected thermistors. If F6 persists with clear airflow, a technician must test it.
What does Daikin F8 mean?
Daikin’s meaning: F8 is an operation halt due to compressor internal temperature. The FTXF manual adds the word abnormality. The compressor itself has been running too hot inside.
Safe to check: Only the outside of the unit. Meanwhile, leave the system off and note how long it ran before stopping.
Stop and call: Internal compressor heat is not an owner fix, so book a licensed technician.
What does Daikin H0 mean?
Daikin’s meaning: The Alira X and FTXF tables print H0 as sensor fault. The older Zena manual calls it a compressor system sensor abnormality.
Safe to check: A single restart. Beyond that, there is nothing an owner can inspect for this one.
Stop and call: The global list gives a disconnected harness or a board fault in the compressor sensor system. A repeat H0 needs testing.
What does Daikin H6 mean?
Daikin’s meaning: H6 is an operation halt due to a faulty position detection sensor. The older Zena manual calls it a position sensor abnormality.
Safe to check: As with other outdoor sensor codes, restart once.
Stop and call: The global list includes a poor compressor cable contact, a faulty compressor and an outdoor board fault. Those need a licensed technician.
What does Daikin H8 mean?
Daikin’s meaning: H8 is a DC current sensor fault. The older Zena manual calls it a DC voltage or current sensor abnormality.
Safe to check: Here too, one restart is the limit.
Stop and call: The global SM-TS3 list links H8 to faulty inverter wiring and an outdoor board fault. That is electrical work inside the outdoor unit.
What does Daikin H9 mean?
Daikin’s meaning: The newer manuals print H9 as a faulty suction air temperature sensor in the outdoor group. The older Zena manual makes the meaning clearer, calling it the outdoor temperature thermistor. So this sensor reads the outside air at the outdoor unit.
Safe to check: The Alira X manual says not to place objects right beside the outdoor unit, so clear anything stored against it. Then restart once.
Stop and call: The global list names a faulty outdoor air thermistor, a loose thermistor connection or a board fault. A repeat H9 goes to a technician.
What does Daikin J3 mean?
Daikin’s meaning: J3 is a faulty discharge pipe temperature sensor. Compare this with F3: there the reading was too hot, while here the sensor itself is the suspect.
Safe to check: First, restart once with the breaker.
Stop and call: Daikin’s global list gives a poor thermistor connection, a faulty thermistor or a board fault. Only a technician can test them.
What does Daikin J6 mean?
Daikin’s meaning: J6 is a faulty heat exchanger temperature sensor in the outdoor group. The older Zena manual spells it out as the outdoor heat exchanger thermistor, so it is the outdoor coil’s sensor, not the indoor one behind C4.
Safe to check: A single restart. However, do not touch the outdoor fins, which the Alira X manual warns can cause injury.
Stop and call: A returning J6 points to the thermistor, its connection or the outdoor board.
What does Daikin J8 mean?
Daikin’s meaning: The Alira X table lists J8 as a faulty liquid pipe temperature sensor. The FTXF table does not include it, so it may not apply to every range.
Safe to check: Similarly, restart once.
Stop and call: The global list puts J7 and J8 down to thermistor faults, poor connections and board faults. Book a technician if J8 returns.
What does Daikin L3 mean?
Daikin’s meaning: L3 is an electrical parts heat fault. The global list describes it as a temperature rise in the electrical component box.
Safe to check: Heat inside the outdoor unit can follow poor airflow. With the breaker off, clear items, leaves and covers from around the outdoor unit, as the manual’s general advice says. Then restart once.
Stop and call: The global list also gives a faulty outdoor fan motor, a power transistor fault and an outdoor board fault. If L3 returns, leave it for a technician.
What does Daikin L4 mean?
Daikin’s meaning: L4 is high temperature at the inverter circuit heatsink. The older Zena manual calls it radiation fin temperature rise. The heatsink carries heat away from the electronics that drive the compressor.
Safe to check: Good airflow around the outdoor unit matters here. Turn off the breaker, then clear anything blocking the inlet or outlet and sweep away built up leaves, which the Alira X manual says should not collect around the unit.
Stop and call: Daikin’s global list gives a short circuit raising the fin temperature or a faulty fin thermistor. If L4 returns with clear airflow, book a technician.
What does Daikin P4 mean?
Daikin’s meaning: P4 is a faulty inverter circuit heatsink temperature sensor. The older Zena manual calls it a radiation fin thermistor abnormality. Where L4 says the heatsink is hot, P4 says the sensor watching it is suspect.
Safe to check: Here too, the only step is a single breaker restart.
Stop and call: The sensor sits in the inverter section of the outdoor unit, so a repeat P4 is technician work.
Which Daikin ducted and other codes are not in the wall split manuals?
None of the Australian ducted documents used here includes a code table, so this group uses Daikin’s global “Simple Self-Diagnosis by Malfunction Code” document (SM-TS3). That is Daikin’s global list, covering room air conditioners, SkyAir, VRV, packaged units and heat reclaim ventilators. It is not specific to Australian models. It also does not say which Australian systems use each code, so treat A3 and E3 as codes you may see on a ducted or other non wall split system.
Many codes above also appear in that global list, so a ducted system can show A1, A6 or U4 as well. This section covers A3 and E3, two codes the Australian split manuals do not list.
What does Daikin A3 mean?
Daikin’s meaning: The global list names the Daikin A3 error code as a drain level control system abnormality. In plain terms, the unit has detected that the water it removes from the air is not draining away as it should.
Safe to check: Look for signs of water, such as ceiling stains or drips near the indoor unit or grilles, and keep anything valuable away from them. The causes Daikin lists are drain clogging or an upward slope in the drain pipe, a faulty drain pump and a faulty float switch or connector.
Stop and call: The Alira X manual tells owners to call their dealer immediately when water leaks from the indoor unit. Do not climb into the ceiling space to inspect the drain pump.
What does Daikin E3 mean?
Daikin’s meaning: E3 is actuation of the high pressure switch, shortened to HPS in the global list. Pressure on the high side rose far enough to trip a safety switch.
Safe to check: Daikin’s first listed cause is a dirty outdoor unit heat exchanger. An owner should not clean the fins, but you can remove anything leaning on the outdoor unit, clear leaves and make sure nothing blocks its airflow. Do this with the power off.
Stop and call: The other listed causes are a faulty high pressure switch, clogged refrigerant piping and a poor connector contact. Those need a licensed technician.
What do Daikin U4 and L5 mean?
These two codes each have a full answer of their own. Here is the short version, with the first safe check for each.
Daikin U4: communication between the units
The Alira X manual lists the Daikin U4 error code as failure of transmission between the indoor unit and the outdoor unit. Put simply, the link between the two units has dropped out, so the system shuts down.
Daikin’s global list gives a few possible reasons. They include faulty transmission wiring, a fault on either board and an outdoor unit that has no power. That last one gives you a first check: look at your switchboard and see whether the circuit for the air conditioner has tripped. Do not touch the outdoor isolator switch or open any panel. For the full set of causes and checks, read what the Daikin U4 code means.
Daikin L5: inverter overcurrent
The Alira X manual calls the Daikin L5 error code output overcurrent. The older Zena manual words it as output overcurrent detection, and Daikin’s global list calls it inverter instantaneous overcurrent on the DC output. Put plainly, the electronics feeding the compressor hit a current limit and switched off.
The global list puts this down to a compressor coil fault, a compressor that would not start, or a faulty inverter board. A brief supply disturbance is worth ruling out with one breaker restart. If L5 comes back, leave the system off. For causes, reset advice and the signs to watch, see the Daikin L5 code in full.
Can I reset a Daikin error code myself?
Yes, within limits. A Daikin wall split has no separate code reset button in the manuals used here. Instead, the Alira X manual tells owners to turn off the power with the circuit breaker, then restart with the remote. That restart is the reset. If the lamp keeps blinking, the manual says to check the code and consult your dealer.
The manuals give no set time to leave the power off. They do say what happens next. After a power failure, the unit resumes by itself in about 3 minutes. Also, straight after the breaker goes back on, it may need about 3 to 15 minutes to prepare.
Why only once
A protective stop can have a passing cause, such as a voltage dip or a storm. The Alira X manual notes that lightning or radio can make the unit malfunction, and a breaker restart can clear that. A code that returns after a clean restart, however, is the system telling you the fault is real.
The newer Zena manual goes further. It says to understand the problem and take measures before resetting an error code, and that this should be done by a licensed installer or your local dealer.
What about the L5 reset button?
Some owners look for an L5 reset button. None of the Daikin Australia owner manuals used for this page describes one. Use the single breaker restart above, and if L5 returns, treat it as a fault. However, for the codes marked Technician only, leave the system off instead of restarting it.
Which Daikin codes mean stop and call a licensed technician?
Some codes leave nothing for an owner to do. In the quick find table these are UA, U0, A3, EA, E6 and F8. Any other code that returns after one restart, or after you have cleared airflow and cleaned filters, joins this list.
The Alira X manual also says to call your dealer immediately in these cases, whatever the display shows:
- The power cord is abnormally hot or damaged.
- An abnormal sound is heard during operation.
- The circuit breaker, a fuse or the earth leakage breaker cuts off the operation often.
- A switch or button often fails to work properly.
- There is a burning smell.
- Water leaks from the indoor unit.
The same manual warns against repairing or modifying the air conditioner yourself, because incorrect work may cause electric shock or fire.
The safety line
Refrigerant work is controlled by law in Australia. The Australian Government’s business licence service lists the Department of Climate Change, Energy, the Environment and Water as the agency. It says a refrigerant handling licence is needed for work on air conditioning equipment that risks releasing refrigerant. That includes servicing and maintenance. The licence comes under the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989. Never open a sealed refrigerant circuit, loosen a fitting or add gas.
Electrical work is controlled too. Energy Safe Victoria says that doing unqualified electrical work is not only extremely dangerous but also illegal, and to always hire a licensed electrician. Every state and territory has its own electrical safety regulator and rules. Never open the outdoor unit’s covers, the indoor unit’s electrical box or your switchboard. If you are unsure what a visit involves, read what to expect from an air conditioner repair.
Where can I find the official Daikin error code list?
Daikin Australia publishes its owner manuals on its operation manuals page. Search there for your model’s range name, then open the “Fault diagnosis by remote controller” page near the back of the manual. That is the official Daikin error code list for your unit.
The main documents behind this page are the Alira X operation manual for the split codes and Daikin’s global Simple Self-Diagnosis by Malfunction Code list for causes and for A3 and E3. The FTXF, Cora and Zena manuals named above fill in the rest.
To find your model number, Daikin Australia’s model and serial number guide shows where the label sits. For manuals, warranty and servicing basics, see the Daikin owner guide. For other brands, browse error codes for other brands.
Codes left off this page
The newer Zena manual also lists a streamer unit error. None of the other manuals used here prints that code, so it is left out. Check your own Zena manual for it. Apart from A3 and E3, codes that appear only in service manuals or commercial lists are not covered here either.
What should you write down before booking a repair?
A clear record saves time for whoever comes out. Before you call, note these details:
- The code exactly as shown, including any extra digits.
- The model numbers from the indoor and outdoor unit labels.
- The mode you were using and roughly when the code appeared.
- Whether a single breaker restart cleared it, and how long it stayed away.
- Anything you noticed, such as noise, ice, water or a burning smell.
With that in hand, a technician can start from the same place the system did. Meanwhile, keep the filters clean and the outdoor unit clear, since several of the codes above can follow from poor airflow.