The 2°C heating capacity on the Zoned Energy Rating Label shows how many kilowatts of heat a split system delivers when it is 2°C outside. Energy Rating says it indicates how the unit copes with cold and frost, which forms below about 5.5°C. The ACT Government suggests asking suppliers about this H2 rating for cold Canberra winters.
Part of our Air Conditioner Maintenance and How Home Systems Work.
You are reading the label on a split system and notice two heating figures in kilowatts, one at 7°C and another at 2°C. Sometimes the 2°C figure is lower, sometimes it is the same, and occasionally it is higher. You may also have heard installers in Canberra talk about an H2 rating. What does the 2°C heating capacity really mean?
The Australian Government’s questions and answers about the Zoned Energy Rating Label explains it directly. In short, a unit’s ability to heat is affected by the outside air temperature, and the 2°C capacity gives an indication of how the air conditioner responds to colder outside temperatures.
The ACT Government’s guide to reverse cycle systems goes further for cold climates. It advises asking your supplier whether a split system has an H2 rating, because that will work efficiently in the Canberra winter.
This guide explains why there are two heating numbers, what affects the 2°C figure, how frost comes into it and how to use the number when choosing a heater for a cold area.
Why are there two heating capacity numbers?
Energy Rating says the top of the label shows heating at two outdoor temperatures and cooling at one. Each figure shows how much heating or cooling the unit can deliver, in kW, at that outdoor temperature.
The reason for two heating figures is that heating output changes as it gets colder. Energy Rating’s Q&A says air conditioners are more efficient at heating when outside temperatures are warmer. For a given input of electricity, heat output is greater at 7°C outside than at 2°C.
Fixed speed units
For fixed speed air conditioners, which either draw full power or nothing, Energy Rating says the heating capacity at 2°C will be lower than at 7°C.
Inverter units
Inverter units can vary their power and capacity. Energy Rating explains that the manufacturer does not have to claim the maximum capacity on the label and may choose to rate the model at a lower capacity. One reason is to market the unit as holding its rated capacity as the outside temperature drops.
The result, in Energy Rating’s words, is that for inverter units the 2°C capacity on the label may be less than, equal to or more than the 7°C capacity.
What the 2°C heating capacity tells you about frost
Energy Rating says the 2°C figures are on the label because they can indicate how well the air conditioner copes with frosting conditions. When the outside air drops below about 5.5°C, frost starts forming on the outdoor coils.
Units deal with frost in different ways. Energy Rating explains that if a unit runs more defrost cycles where it switches off completely, that lowers its tested capacity at 2°C. If it manages to defer defrost cycles, for example by speeding up the outdoor fan to blow moisture off the coils, that raises its tested 2°C capacity.
So a strong 2°C figure suggests a unit that keeps delivering heat on cold, damp mornings, rather than stopping often to defrost.
What does H2 heating capacity mean in the ACT guide?
In its comparison table of split, ducted and multi-head systems, the ACT guide says smaller split systems have excellent efficiency, and to look for H2 CoP2 as a sign the unit is well suited to Canberra’s winters. Later it repeats the advice: if you are installing a split system only, ask your supplier if it has an H2 rating, as this will work efficiently in the Canberra winter.
The ACT guide does not explain the term, but EECA, New Zealand’s regulator for the same Zoned Energy Rating Label, lists H2 as the low temperature heating test condition, with an outdoor temperature of 2°C. H1 is the standard 7°C test. The ACT guide does not set a specific H2 number to aim for. Treat it as a prompt to ask the supplier about the unit’s performance at 2°C, and to compare that between models.
What the 2°C figure does not tell you
- It is not an efficiency rating. Energy Rating says the capacity numbers do not show how much electricity the unit draws to produce that heat.
- Efficiency is in the stars. Energy Rating says efficiency across the range of temperatures in each climate zone is captured in the star ratings.
- It is not a sizing tool on its own. Room size, windows, insulation and shading all matter.
Use the 2°C capacity alongside the heating stars for your zone, not instead of them. Energy Rating says the label shows a seasonal star rating for three climate zones, hot, average and cold, and its Energy Rating Calculator helps you identify your climate zone.
Why the old label did not show this
Energy Rating explains that on the old Energy Rating Label, heating stars were based on performance at a single outdoor temperature of 7°C. The Zoned Energy Rating Label instead rates performance across a range of outside temperatures typical of each climate zone. Adding the 2°C capacity figure gives buyers in colder areas extra information about how a unit behaves when it is genuinely cold outside.
Energy Rating also says there is no direct comparison between star ratings on the old label and the zoned label. If you are replacing an older unit, do not assume the same number of stars means the same performance.
How to use the 2°C heating capacity when buying
- Work out the heating output you need. The VEU program’s sizing fact sheet gives a starting guide by room size, and a licensed installer can refine it.
- Check both heating figures. Compare the 7°C and 2°C capacities on each model’s label.
- Favour a strong 2°C figure in cold areas. If you live somewhere with frosty mornings, a unit whose 2°C output is close to or above what your room needs is a better fit.
- Compare heating stars for your zone. Use the Energy Rating Calculator to find your zone.
- Ask the supplier. In the ACT, ask about the H2 rating, as the ACT guide suggests.
Is this the same as defrost mode?
They are linked. The 2°C test captures how much heat a unit delivers when frost and defrosting are part of the picture. On a real winter morning, you may notice the indoor fan stop for a while during a defrost. Mitsubishi Electric Australia’s defrost cycle article says this is a normal function, not a fault.
Sizing & Buying: when to call a licensed technician
- You need a heat load assessment for a cold room or a home in a frosty area.
- Your current unit stops for defrost very often and the room never gets warm.
- Ice stays on the outdoor unit after a defrost pause.
- Heating output has dropped compared with previous winters.
Do not chip ice off the outdoor unit or open any panels. Leave refrigerant and electrical checks to licensed technicians.
Related answers
- Zoned Energy Rating Label heating stars, what they mean for you
- What size split system do you need for heating a room?
- How much electricity does an air conditioner use each hour
- Carrier split system heating in cold weather, -15°C and star ratings
- How much power does a 2.5 kW air conditioner use?
- Is it worth upgrading an old reverse cycle unit for better heating?
Frequently asked questions about 2°C heating capacity
What does the 2°C heating figure on an air conditioner label mean?
It shows the heating output in kW at an outdoor temperature of 2°C. Energy Rating says it indicates how the unit responds to colder outside temperatures and frosting conditions.
Why is the 2°C capacity sometimes higher than the 7°C capacity?
Energy Rating says inverter units may be rated below their maximum at 7°C, so the 2°C figure may be less than, equal to or more than the 7°C figure.
What is an H2 rating on a split system?
H2 is the name of the low temperature heating test, run at 2°C outside. The ACT Government guide links an H2 rating with a unit being well suited to Canberra’s winters, and advises asking your supplier about it.
Does a higher 2°C capacity mean lower running costs?
Not by itself. Energy Rating says capacity figures do not show electricity use. Check the heating stars and kWh for your climate zone.
Sizing & Buying: the key points
The 2°C heating capacity on the Zoned Energy Rating Label shows how much heat a unit delivers when it is cold outside. Energy Rating says frost starts below about 5.5°C, and the 2°C figure reflects how well the unit handles it.
In cold areas, look for a strong 2°C figure and good heating stars for your zone. In the ACT, ask your supplier about the H2 rating.
For sizing basics, read our guide on what size split system you need, and see how a reverse cycle air conditioner works to understand the heating cycle itself.