You asked
We'll solve it.Opening your answer
Ducted heating · Rinnai · Error & Fault Codes

Rinnai Error Codes: Find Your Heater, Then Your Code

Reading time 19 minUpdated 28 Nov 2026For Australian homesBy Checked against sources by our review team, 28 Nov 2026
Short answer

The same Rinnai code can mean different things on an Energysaver, a portable heater, a ducted heater and the Rinnai Touch Wi-Fi module. Identify your heater, then find the code, Rinnai’s own meaning, the safe owner check, the gas safety steps from Energy Safe Victoria, and when a licensed gasfitter is needed.

Rinnai error codes are two digit numbers a Rinnai gas heater shows when it detects a fault. Two you will meet early are error code 12 and error code 11, which both relate to lighting and keeping the flame. But here is the catch. The same number can mean different things on different Rinnai heaters, so a code is only useful once you know which heater you own.

Code 53 shows this best. On an Energysaver room heater it means a faulty spark sensor. On a ducted gas heater it means a lockout after repeated overheating. On a Rinnai Touch Wi-Fi module it means the module has switched to setup mode. In short, three products, three meanings, one number.

So this guide starts with a quick way to identify your heater. It then gives each family its own code table, with the meaning and owner step from Rinnai’s own documents. The gas safety section comes early, because some codes are about air and flame, not convenience.

Which Rinnai heater do I have?

Rinnai’s gas heating range in Australia falls into a few families. Each one has its own error code sheet. Use the cues below, then confirm with the model number on the rating label.

Energysaver flued room heater

An Energysaver sits in the room it heats and has a flue that vents outside through a wall. You will see a flue terminal on the outside wall. The control panel has a digital display, and a fan filter sits at the rear. Model numbers start with RHFE, such as the RHFE-309FT3, 559FT3, 561FT3 and 1005FT3 listed in Rinnai’s Energysaver FT operation manual. Jump to the Energysaver room heater codes.

Portable unflued convector heater

A portable heater has no flue at all. It plugs into a bayonet gas fitting with a flexible hose and has carry handles. Rinnai’s portable error code sheet covers the Avenger 25, Dynamo 15, Enduro 13 and Granada 252. The operation manual lists model codes such as RCE-671TR for the Avenger 25. Jump to the portable heater codes.

Ducted gas heater

A ducted heater sits in the roof, under the floor or outside. Warm air comes through floor or ceiling registers, and air returns through a grille. You run it from a wall controller, such as a Networker N-C3, N-C6 or N-C7 Touch. Rinnai now sells its ducted gas heaters under the Brivis name, and its error code sheet carries the Brivis by Rinnai heading. Jump to the ducted heater codes.

Rinnai Touch Wi-Fi module

The Touch module is not a heater. It is a small box, often in the ceiling space, with PWR, BUS and WIFI lamps on the front. It links a ducted system to the Rinnai Touch app. Its codes appear on the wall controller, so they can look like heater codes. Jump to the Rinnai Touch codes.

For a wider look at each range and its documents, see the Rinnai gas heater owner guide. Rinnai air conditioners use their own fault lists, and none of the numbers on this page apply to them.

What does Rinnai error code 12 mean?

Rinnai error code 12 has two meanings, depending on the heater.

  • Energysaver room heater: flame failure. Rinnai’s step is to check that the gas supply is turned on.
  • Portable heater: incomplete combustion. Rinnai’s step is the same as for code 11: check the gas supply is on, switch the heater off and on again, and book a service call if it fails to ignite after four attempts.

So the Rinnai Avenger 25 error code 12 is incomplete combustion, not flame failure. That difference matters, because incomplete combustion is about how the gas is burning. If a portable heater shows 12 more than once, stop using it and arrange a service. The details for each are under Energysaver code 12 and portable code 12.

And Rinnai error code 11?

By comparison, Rinnai error code 11 is simpler. On both the Energysaver and the portable sheets, it means ignition failure. Rinnai says to check the gas supply is turned on, then switch the heater off and on again. If the error persists, or the heater fails to ignite after four attempts, you need a service call.

Is it safe to keep using a Rinnai heater that shows a code?

Many codes mean the heater has already stopped itself. Some codes are routine, such as a dusty filter. Others are about air supply, combustion or the flue, and those need care. Read this section before you restart anything.

Rinnai error code 10 on a portable heater

Rinnai error code 10 appears on the portable sheet as oxygen shortage. Rinnai’s step is to clean the filters and ventilate the room, and to book a service call if it happens again.

The portable manual explains why. These heaters are unflued, and an oxygen depletion sensor cuts the gas if the oxygen level in the room drops below a preset limit. The manual says the room must be correctly ventilated, and that fixed ventilation must conform to local regulations.

The same manual says not to use these heaters in a bedroom, bathroom, toilet, combined living and sleeping area or sauna. It sets a minimum room size for each model, for example 62.5 cubic metres for the Avenger 25. It also says not to connect an LPG cylinder indoors.

Carbon monoxide

Energy Safe Victoria’s page Heating your home with gas says carbon monoxide is a gas you cannot see or smell. It also says unflued heaters release combustion products into the room, so the room must be adequately ventilated when one is in use.

The regulator’s Be Sure page lists dizziness, nausea and headaches as symptoms, and notes they can look like a winter cold. If you suspect carbon monoxide, it says to:

  • Leave the house immediately and get into fresh air.
  • Turn off gas appliances and open windows and doors, if you can.
  • Contact Nurse-on-Call or a doctor, or call 000 in an emergency.
  • Not use the heater again until a qualified gasfitter has checked it.

For more on the signs, read carbon monoxide poisoning from a gas heater. Energy Safe Victoria also says a carbon monoxide alarm helps but should never replace regular servicing.

If you smell gas

Energy Safe Victoria’s gas emergencies page gives these steps for a suspected leak inside a home.

  • Turn off the gas at the meter, or at the cylinder for LPG, only if it is safe.
  • Put out all flames, and do not smoke or strike matches.
  • Do not operate electrical switches or devices.
  • Open doors and windows, and keep people away.
  • Call your gas distributor straight away, using the number on your gas bill, or the supplier’s emergency contact for LPG.

The steps are also covered in what to do if you smell gas. Rinnai’s manuals give the same direction for a gas escape: isolate the gas supply and arrange a service call.

The rule on gas work

Energy Safe Victoria is the regulator in Victoria, and each other state and territory has its own gas safety regulator. Gas work, including finding faults on the gas side of a heater, is for a licensed gasfitter. Energy Safe Victoria suggests asking to see the gasfitter’s licence card, and says gasfitter licences can be checked online.

Never open a heater, remove its panels, or touch the gas valve, burner or flue. Never bypass a safety device. Rinnai’s Energysaver manual says the heater contains no user serviceable parts.

What do Rinnai Energysaver error codes mean?

Rinnai’s Energysaver FT and FDT error code sheet and its Energysaver FT operation manual print one table. The room heater codes and the Energysaver codes are therefore the same list. So for Rinnai room heater codes, this is the table to use. For care and settings, see the Rinnai room heater guide.

Rinnai’s general note for Energysaver codes is short. You may be able to clear the message by turning the heater off, then on again. If the message remains or returns on the next operation, Rinnai says to arrange a service call.

Energysaver code 11: ignition failure

The heater tried to light and could not. Rinnai says to check the gas supply is turned on, then turn the heater off and on again. If the error persists, you need a service call.

The operation manual adds a useful detail. On first use, air left in the gas line can stop ignition, and the spark only runs for 15 seconds. If the heater still fails to ignite after four attempts, Rinnai says to contact it, as a service call may be required. A Rinnai gas heater error code 11 straight after installation can have this simple cause.

Energysaver code 12: flame failure

Here the heater lit, but the flame did not stay alight. Rinnai’s listed step is to check that the gas supply is turned on. On LPG, that includes checking the cylinder.

The owner part stops at the gas supply. A Rinnai fault code 12 that returns with gas on needs a service call, because the flame sensing parts are inside the heater, and Rinnai’s manual says it has no user serviceable parts.

Energysaver code 14: filter blockage or overheat

Rinnai says to clean the filter or filters, and to arrange a service call if the error persists. The manual explains that when the filter blocks during operation, the ON indicator flashes and the display shows 14.

First, turn the heater off and let it stop before you touch the filter. Rinnai warns not to remove or clean filters while the heater is running. It says to clean them weekly in the heating season, with a duster or vacuum for dry dust. For oily lint, the manual says to wash the filter in mild detergent and dry it before refitting. Also, the 1005FT3 has two filters.

Energysaver code 16: room overheat

The room itself got too hot. Rinnai’s step is to lower the room temperature to less than 40°C. Then open a door, let the space cool, and check nothing is blocking the warm air outlet.

Energysaver code 99: flue terminal blocked

Rinnai says the owner should check that the flue terminal is free of any obstructions, and to book a service call if the error persists. The terminal is on the outside wall.

The manual asks owners to check the terminal regularly for plant growth and other obstructions, and to keep snow clear of it in snowy areas. Steam from the terminal on cold days is normal, it says. Clear only what you can reach safely from outside, such as leaves or a plant. Do not remove the terminal cover or touch the flue pipe. For an obstructed flue terminal, Rinnai’s troubleshooting chart says to clear the obstruction. For a disconnected flue manifold, it says not to use the heater and to arrange a service call.

Energysaver codes that always need a service call

CodeRinnai’s probable cause
30, 33, 34, 35Overheat temperature sensor faulty
31, 32Room temperature sensor faulty
40Sensor tube failure
49Sensor breakdown
53Spark sensor faulty
61Combustion fan faulty
62Convection fan faulty
70Faulty ON-OFF switch
71, 81Faulty solenoids
72Flame detection circuit fault
73Communication error

For each of these, Rinnai’s sheet says to book a service call. There is no owner check beyond noting the code.

What do Rinnai portable heater codes mean?

Rinnai’s portable heater sheet covers the Avenger 25, Dynamo 15, Enduro 13 and Granada 252. The portable operation manual says that when a fault occurs, the heater shuts down and shows a pair of flashing digits. The digits show on the heater’s digital display, and the ON indicator also flashes red.

Portable code 3: tilt switch activated

The manual says the tilt switch cuts the gas if the heater is knocked over, while the fan keeps cycling. Rinnai’s step is to make sure the heater is level and upright, and to book a service call if it happens again.

Next, check the floor under it is flat and firm. For example, a thick rug or uneven tiles can tip it. Do not move the heater while it is running or while its fan is still cycling, as the manual warns.

Portable code 10: oxygen shortage

Rinnai’s step is to clean the filters and ventilate the room, with a service call if it repeats. Read the safety section above before you restart. Code 10 means the oxygen depletion sensor has acted, so the room’s air supply needs attention first.

Portable code 11: ignition failure

As with the Energysaver, Rinnai says to check the gas supply is turned on and switch the heater off and on again. If it still fails to ignite after four attempts, book a service call.

Portable code 12: incomplete combustion

Rinnai’s step reads “as above”, meaning the same as code 11. Even so, do not keep relighting a portable heater that shows 12. Ventilate the room, and if the code comes back, leave the heater off until it has been serviced.

Portable code 14: filter blockage or overheat

Rinnai says to clean the filters, with a service call if the error continues. The manual says to unplug the heater before cleaning. Filter 1 lifts out after removing a retaining screw, and Filter 2 stays in place and is vacuumed. Rinnai warns not to run the heater with the filter warning lamp on.

Portable code 16: room overheat

Rinnai’s step is to lower the room temperature to below 40°C.

Portable code 18: thermocouple output error

Rinnai lists three possible causes: not enough gas supply, the wrong gas type, or a fault needing a service call. The manual says to check the label on the rear of the heater for the gas type. It also says to check the gas type if you move house. If you are in doubt about the gas type, the manual says to check with your local gas authority.

Codes 0 and 73: press twice to reset

Code 0 means a mains power failure during operation. Code 73 is a communication error. For both, Rinnai says to press the ON-OFF button twice to reset the heater, and the manual adds a service call if 73 repeats.

Portable codes that always need a service call

  • 13: combustion control faulty.
  • 31: room temperature sensor faulty.
  • 32, 33, 34: overheat temperature sensor faulty.
  • 62: faulty fan motor.
  • 70: ON-OFF switch faulty.
  • 71: solenoids faulty.
  • 72: flame detection circuit fault.

What do Rinnai ducted gas heater codes mean?

The Brivis by Rinnai gas ducted heating error code sheet is short. Codes show on the wall controller. For symptoms that come without a code, see Rinnai ducted heater troubleshooting.

Codes 40, 41 and 42: overheat temperature

The sheet says the fan will run at maximum speed when this happens. The owner checks are all about airflow.

  • Make sure enough outlets are open on the duct system.
  • Check the floor or ceiling registers and baffles are fully open.
  • Check the return air filter, if fitted, is the right size, clean and not blocked.
  • Move anything placed in front of the return air grille.

The sheet does not list 43, but the Brivis heating owner’s manual (Issue F) groups it with 40 to 42 as an overheat code, so use the same airflow checks.

Codes 46, 47 and 55: ignition failure

For all three, the sheet’s user remedy is a service call. There is no owner step listed, so do not keep restarting the heater.

Code 50: locked out after four ignition attempts

Rinnai says to use the reset button to restart the heater. If the error appears again, the sheet lists these checks.

  • The gas is on at the meter and at the appliance gas cock.
  • Other gas appliances, such as a cooktop or hot water service, are working.
  • On LPG, the cylinders have gas and the cylinder valve is open.
  • Gas is reaching the home. Your gas supplier can confirm any maintenance or supply problem.

The sheet adds that the heater may need a general service.

Code 53: locked out after repeated overheating

On a ducted heater, Rinnai describes 53 as locked out because of multiple overheat occurrences. Its checks match codes 40 to 42: open outlets, open registers and baffles, and a clean, unblocked return air filter. Then reset the appliance. If 53 persists, Rinnai says to contact your installer.

Before you do, rule out the Touch module. If the system has a Rinnai Touch Wi-Fi module, code 53 can be a module message instead. The way to tell them apart is in Rinnai Touch error code 53 below. An Energysaver room heater also uses 53, for a faulty spark sensor.

Code 56: locked out by the pressure switch

The sheet says gusty wind can open the pressure switch by blowing air back down the flue. Its owner checks are a blocked flue pipe and, on SP6 models, blocked condensate piping. Only look at what you can see safely from the ground. A flue on a roof is not an owner job, and a heater that keeps locking out on its flue needs a licensed gasfitter.

Any other ducted code

The sheet says any other code on the screen could mean the heater has stopped because of a fault in the electronic control module. It may be reset at the power supply. If it persists, Rinnai says to contact Rinnai or Brivis customer care.

What do Rinnai Touch codes 51, 52, 53 and 54 mean?

These come from the Rinnai Touch Wi-Fi Kit Installation and Configuration Manual. It says the module’s codes will not disrupt the heater’s operation and may clear after some time. In other words, they are Wi-Fi setup messages, not heater faults. The module works with Rinnai and Brivis ducted gas heating, add-on cooling and evaporative cooling systems that have a wired Networker controller.

Touch code 51: configuration error

The manual describes 51 as a Touch Wi-Fi Module configuration error. Its action is to check the network name and password you entered, and otherwise replace the module.

Touch code 52: router not found

The module tries to reach its assigned router for three minutes. If it cannot find the router after 30 seconds, it registers 52. The manual’s action is to check the router, and the distance between the router and the module. It says the module should be within 10 metres of the router.

Those two checks are the owner steps. Make sure the router is switched on and working for other devices, and that it has not been moved further from the module.

Rinnai Touch error code 53: module in setup mode

The manual says the module has switched to its configuration mode because it could not find its assigned router. When this happens, the module alternates between searching for about three minutes and setup mode for about two minutes.

The controller tells you which 53 you have. On an N-C7 Touch controller, a warning icon opens the message “Networker fault detected, Code#53”. On an N-C6 or N-C3, pressing Fn then 1 scrolls “Sensor fault, n11 Code#53”. The manual gives this message as the sign that code 53 comes from the module. The manual’s fix is to reconfigure the module through the Rinnai Touch app, which steps you through it. The manual raises this code in the context of a replaced router.

Touch code 54: not yet set up

The manual says 54 means the module is running in configuration mode because it has not yet been set up. It stays that way until it is connected to a router through the app.

Other Touch module codes

The same manual lists 50 for no configuration data, 55 and 56 for internal communication errors, and 57 to 62 for remote access and server errors. Its action for each is to replace the module if the problem persists. Note that ducted heater codes 50, 55 and 56 mean something else entirely, so check whether the controller message names the module.

Leave the module where it is mounted unless you can reach it safely. The manual says it must be installed indoors by a qualified person.

How do I clear a Rinnai error code?

Each family clears differently. Use only the method Rinnai gives for your heater.

  • Energysaver: turn the heater off, then on again. If the message remains or returns on the next operation, arrange a service call.
  • Portable: for codes 0 and 73, press the ON-OFF button twice. For code 11, turn it off and on, and stop after four failed attempts.
  • Ducted: for code 50, use the reset button. For code 53, reset after the airflow checks. Other codes may be reset at the power supply.
  • Touch module: reconfigure it through the Rinnai Touch app. Its codes may also clear on their own.

Why repeated resets are a bad idea

Rinnai’s sheets put a limit on retries. The portable and Energysaver documents say to book a service call if the heater fails to ignite after four attempts, or if a message returns on the next operation. The ducted sheet says 53 that persists after a reset goes to the installer.

None of Rinnai’s documents asks owners to keep retrying. Once a code comes back, each one points to a service call.

Which Rinnai codes need a licensed gasfitter?

Based on Rinnai’s own sheets, these codes have no owner step beyond safe checks, and need a service call.

HeaterCodes
Energysaver12 or 11 that returns with gas on, 14 or 99 that returns after cleaning, and 30 to 35, 40, 49, 53, 61, 62, 70 to 73, 81
Portable3, 10 or 12 that repeats, 11 after four attempts, 13, 18 that is not a supply issue, 31 to 34, 62, 70 to 72
Ducted46, 47, 55, a repeat of 50 or 53, 56 that keeps returning, and any unlisted code that persists

Any code that comes with a gas smell, soot, a changed flame colour or symptoms of carbon monoxide goes straight to the safety steps above. Energy Safe Victoria lists a flame that changes from its usual colour as a sign a heater may be unsafe.

Servicing between codes

Energy Safe Victoria says to have a gas heater serviced at least once every two years by a qualified gasfitter, including a test for carbon monoxide leakage. Rinnai’s manuals also recommend a service every two years. To see what that visit covers, read what a gas heater service visit covers.

Where can I find the Rinnai Australia manual for my model?

Rinnai Australia publishes operation manuals and error code sheets for its gas heaters on its website. Search with the model number from the rating label. Each family has its own sheet, which is why the code tables on this page are split by heater.

Keep the sheet for your heater somewhere handy, such as on your phone. When a number appears, check the family first, then the code. Do only the owner checks Rinnai lists, and leave every gas, flue and burner job to a licensed gasfitter.

Not sure what to do?Call us