An evaporative cooler needs somewhere to send the air. Learn how it works, the Braemar and Bonaire controller modes, Bonaire’s minimum exhaust area for open windows and doors, what makes a cooler colder on hot days, running cost estimates from the SA Government and the basics of keeping it working.
Part of our Air Conditioner Maintenance and How Home Systems Work.
How to use evaporative cooling well depends on one thing more than any setting: letting the air out. An evaporative cooler pushes fresh, water cooled air into the house, and that air needs somewhere to go. So this guide starts with how the system works, then the controller modes, then windows and doors, and finally the levers the manuals list for getting more cooling on a hot day. The facts come from Bonaire’s Navigator controller owner’s manual, Braemar’s SpectroLINK owner’s manual from Seeley International, and the South Australian Government’s cooling advice.
How does evaporative cooling work?
Bonaire’s manual puts it in one line. The principle of evaporative cooling is to supply fresh air, washed through the filter pads to cool it. The cool fresh air then circulates through the home, replacing the warmer air.
The South Australian Government describes it the same way: evaporative air conditioners use water and a fan to blow cool, humidified air into the home. It adds that they work well in dry weather but can be less effective when it is humid, and that they need good ventilation.
Why this changes how you use it
An evaporative cooler brings fresh outside air into the house, as Bonaire’s description shows. In contrast, the South Australian advice says refrigerative air conditioners work best with closed windows, while evaporative air conditioners are more effective if you open some doors and windows to increase airflow. That single difference is why a split system habit, such as closing every window, does not suit an evaporative cooler.
For a fuller explanation of the technology, see what evaporative cooling is.
How do I start an evaporative cooler?
The steps depend on the controller. Here are two that the manuals describe in detail.
On a Braemar SpectroLINK
- Open the controller door and press AC MODE to select COOL, if the controller also runs a heater.
- Press ON OFF to turn the controller on.
- Press MAN AUTO to choose manual or automatic operation.
The manual says that with the pump on, the controller flashes WAIT at the start of a cooling cycle. During that time, the cooler tank fills with water and the pads are pre wet. A snowflake symbol shows when the pump is on. So expect a short wait before the air feels cool.
On a Bonaire Navigator
The Navigator manual says the controller runs a ducted evaporative air conditioner in four modes: Manual, Thermo, Boost and Fan. Turn the Navigator on, press MODE until the mode you want shows, and press ENTER. If your system has only an evaporative cooler, the Navigator shows the Cool icon.
What do the cooler modes do?
Both manufacturers separate cooling from fan only ventilation, and both offer a manual and an automatic option.
| Mode | What the manual says it does |
|---|---|
| Braemar MANUAL, pump on | You set the fan speed. Evaporative cooling mode. |
| Braemar MANUAL, pump off | Ventilation only. COOL VENT turns the pump on or off. |
| Braemar AUTO | You set the cooling output. The cooler controls the pump and fan from the temperature sensed at the controller. |
| Bonaire Manual | You set the fan speed, with 7 levels. |
| Bonaire Thermo | You set a relative comfort level with bars. The fan adjusts itself. |
| Bonaire Boost | Pump and fan run at maximum output. |
| Bonaire Fan | Fan only, with 8 levels. The unit does not cool. |
How Bonaire’s Thermo mode behaves
Thermo mode does not use a temperature in degrees. Instead, the manual says minimum bars mean warmer and maximum bars mean cooler, so you set it to the point where you feel comfortable. As the room nears that comfort level, the water pump turns off while the fan keeps running. The fan only stops if the room is more than 1 degree below the chosen level.
Fan only as a ventilator
The South Australian advice notes that an evaporative cooler can also run as a large fan without the water cooling. On a Braemar, that is MANUAL with the pump off. On a Bonaire, it is Fan mode.
Timers
Braemar’s SpectroLINK can start and stop the cooler at set times, in MANUAL mode for cooling or ventilation, or in AUTO mode for cooling only. The Bonaire Navigator manual also describes timed operation and programs for the cooler.
How many windows should be open for evaporative cooling?
Bonaire’s manual answers with an area, not a number of windows. It says it is essential for successful operation that there are sufficient exhaust openings in the area being ventilated, and that open doors and windows will usually provide this.
Bonaire’s minimum exhaust areas
The manual gives a minimum exhaust opening by cooler size:
| Cooler model size | Minimum exhaust area |
|---|---|
| Small | 0.85 square metres |
| Medium | 1.19 square metres to 1.48 square metres |
| Large | 2.02 square metres |
So the number of windows depends on their size. Add up the open area of the windows and doors you leave open, and compare it with the figure for your cooler. Your cooler’s size is on its data plate, which Bonaire says is inside the cooler near the electronic controls.
When windows are not enough
Bonaire recommends ceiling vents or exhaust fans wherever there is any doubt about having enough exhaust area. It says ceiling exhaust fans or vents should have a capacity equivalent to the cooler’s.
Where to open them
Braemar’s troubleshooting table gives the placement rule. For inadequate cooling, it lists not enough doors and windows open in the house, and the remedy is to open more doors and windows, particularly in the areas that need more cooling.
Signs the exhaust is too small
Bonaire’s problem solving chart lists excessive humidity as a symptom. Its first cause is inadequate exhaust, and the remedy is to provide more open area to exhaust stale air. If the house feels clammy while the cooler runs, open more windows before changing anything else.
How can I make an evaporative cooler colder?
The manuals list a small set of levers for colder air. None of them involves changing the water setup yourself.
Use the right mode
Bonaire’s Boost mode runs the pump and fan at maximum output. On a Braemar in AUTO, press the up arrow to increase the cooling output. In Braemar MANUAL, check the pump is on, shown by the snowflake. With the pump off, the cooler is only ventilating.
Give the air somewhere to go
Exhaust is the first lever, as the windows section above explains. Braemar’s first remedy for inadequate cooling, after checking the water, is to open more doors and windows in the areas that need cooling.
Check the pads are wet
Braemar lists dry pads as a cause of inadequate cooling. Its remedies are to check the water flow to the pads and make sure the water supply to the cooler is on. Bonaire’s chart also lists dry filters and dirty filters, meaning the pads, as causes of inadequate cooling, and says to place a service call for both. Bonaire adds that an incorrectly set DIALFLO valve can cause a lack of cooling, and that its setting is a job for the dealer or installer.
Accept the weather limit
Humidity sets a ceiling on what any cooler can do. Braemar’s manual says it is normal for an evaporative cooler not to cool as effectively on days of high ambient humidity as on days of low humidity. The South Australian advice says the same. On very humid days, Bonaire’s chart suggests turning the pump off if humidity indoors becomes excessive because outside humidity is high.
For how well evaporative cooling copes in different climates, see is evaporative cooling effective.
What extra features do some coolers have?
Bonaire’s Navigator manual lists extra functions for its Pinnacle coolers. They explain some behaviour that can look odd.
- Humidity control: press and hold MODE while the unit runs.
- EC motor delay: when the fan motor comes on, there is a 5 minute delay to protect the motor from frequent power ups.
- Salinity control: on by default from the factory.
- Ioniser: on whenever the fan runs.
- Pad clean: with the fan speed at zero, so the screen shows pump only, press MODE to start a 20 minute pad clean cycle.
- Exhaust: not enabled by default. If enabled, holding MODE with the unit off runs the motor in reverse at 50 percent speed.
- Service due: not enabled by default. If enabled, a spanner shows after 700 hours of operation to say a service is due.
If a Pinnacle cooler seems slow to start its fan, the 5 minute motor delay is the likely reason, as the manual describes it.
Is water dripping from the cooler normal?
It can be. Bonaire’s problem solving chart lists water leaking from the overflow, and gives two causes. A leaking float valve needs its adjustment checked or its seal replaced. Water draining from the pads is normal operation. Its maintenance notes add that some discharge from the overflow after shut down is normal, because water drains back from the pads.
Water droplets in the air stream are different. Bonaire lists a loose delivery tube or a break in the tubing, both needing a service call, or too much water delivered to the pads, fixed by adjusting the DIALFLO valve. Leave those adjustments to the dealer or installer, as the manual suggests for the flow rate.
What happens at the start and end of the season?
Braemar’s manual says draining the cooler at the end of summer is not required if it has an automatic drain valve. If it has a bleed system instead, it lists maintenance before and after every summer, written for the service agent. The pre season steps include turning the power off, removing the pad frames, gently washing the pads and replacing them if they are in poor condition. It warns never to run the cooler with the pad frames removed.
Bonaire’s manual says that with an Aquamiser fitted, there is no need for regular checks during summer. However, it says this does not remove the owner’s responsibility to have the unit serviced every year.
What if the cooler will not start?
Bonaire’s problem solving chart gives the first checks for a unit that fails to start. After a blackout, wait until power is restored. The chart also lists a tripped circuit breaker and a blown fuse among the causes. An electrical fault needs a service call. If the pump fails to start, the chart lists a seized or burnt out pump, and both need a service call.
On a Braemar SpectroLINK, a flashing spanner while cooling means the cooler’s diagnostic software has found an operational fault. The manual says to make sure the water supply and power to the cooler are on, and that the cooler drain pipe is not blocked. Then record the number shown where the time usually appears, and quote it with the cooler’s serial number if you call for service.
Zones and multiple controllers
Ducted heating habits can mislead here too. Braemar’s manual says that in systems with more than one SpectroLINK, only the master controller can run the evaporative cooler, and zones do not operate in evaporative cooling mode. So closing zones will not direct the cooled air on that system. Opening and closing windows does that job instead.
What does an evaporative cooler cost to run?
The South Australian Government gives indicative figures, including water, on a flat electricity rate. It lists about 5 to 7 cents per hour for portable evaporative units, and about 44 to 59 cents per hour for ducted evaporative systems. It describes evaporative coolers as using small amounts of energy, with a small additional water cost.
The page says the figures are based on AGL’s standing retail contract electricity rates and are a guide only. It was last updated on 15 December 2023. Your cost will depend on your tariff, the size of the system and how long it runs.
What keeps an evaporative cooler working well?
Good cooling also depends on maintenance. The manuals split it between automatic functions, owner checks and service work.
Automatic drain and water management
Braemar’s manual says a cooler with an automatic drain valve drains its water by itself, to keep the water fresh. It lists the triggers: high water salinity on Braemar and Breezair models, a preset time on Coolair models, or the cooler being off for a continuous 72 hours. You can also start a manual drain with the controller off and the door closed, by pressing the up and down arrows together. When the cooler restarts, there is a delay while the tank refills.
Bonaire’s manual says all evaporative air conditioners need some water to go to waste, to prevent mineral build up. It warns that white deposits on the pads indicate high mineral content, and its chart says to call the installer.
Servicing and the roof
Braemar’s manual asks for a check after the first year, and then every two years as routine maintenance. It warns that Seeley International recommends maintenance by a service agent, because climbing onto the roof is hazardous. Bonaire’s manual asks owners to have the unit serviced every year to check its function and keep it free of mineral deposits, and warns that wet roofs are dangerous. For a maintenance plan, see evaporative cooler maintenance. For what a service visit covers, see the evaporative cooling service guide.
Bonaire’s maintenance section shows what that service involves. It describes hosing the pads from both sides to remove salts, dust and pollen, more often in dusty areas. It also covers keeping the water tank free of sediment and algae, checking the pump strainer, and checking that the fan spins freely. Because these jobs happen on the roof, they belong with a service agent.
Odours and new pads
Both manuals say some odour from new pads is normal. Braemar says to allow time for the pads to condition by running the cooler. Bonaire’s chart also lists a cooler sited near an odour source, with the remedy of removing the source.
Does the same advice apply to every brand?
The principle is the same, but controllers and modes differ between brands. If you have a Brivis evaporative system, see how Brivis evaporative cooling works. Check your own manual for the modes and the exhaust area for your model.
Electrical and roof safety
Bonaire’s manual says only a qualified electrician should carry out electrical connections and maintenance. Energy Safe Victoria says electrical work is not a do it yourself job. Keep roof work, pad changes and water adjustments for a service agent.
What is the short version?
Open windows and doors in the rooms you want cooled, enough to match the exhaust area your cooler needs, which Bonaire puts at 0.85 square metres to 2.02 square metres by size. Choose a cooling mode with the pump on, and use Boost or a higher cooling output on hot days. Check that the pads are wet. Expect less cooling on humid days, and switch to fan only when the air is already moist. For anything on the roof, call a service agent.