How Does Brivis Evaporative Cooling Work? Running It and the Water It Uses

Reading time 12 minUpdated 28 Nov 2026For Australian homesBy Checked against sources by our review team, 28 Nov 2026
Short answer

How Brivis evaporative cooling works, from the pads, pump and pre-wet to the shut down flush, how to run it from a Networker, programmable or manual wall control, how many windows to open, and what Brivis says about water use and AquaSave.

How does Brivis evaporative cooling work? A roof unit draws in outside air, passes it through wet pads to cool it, and sends it down ducts into the house. This page explains that process, then shows how to run a Brivis evaporative cooler from each type of wall control, and what Brivis says about the water it uses.

The facts come from two Rinnai documents. The first is the Brivis Evaporative Air Coolers Operation Manual, Issue F, August 2019, which covers the Contour, Promina, Advance, Advance Plus and AD series. The second is the Brivis evaporative cooling brochure. Rinnai publishes both, because Brivis is a Rinnai brand. Models and features differ across the range, so the series are named where it matters.

How does Brivis evaporative cooling work?

The brochure describes it simply. Brivis evaporative cooling is a central cooling unit connected to outlets around the home. The unit draws in fresh air and passes it through moistened pads, which cool and filter it. The air then travels through the ductwork into your rooms.

Because the air comes from outside, the manual says 100 percent fresh cool air enters the home. As it moves through the house, it draws the heat out, so doors or windows must be open to let that heat escape. The brochure adds that a Brivis evaporative cooler contains no synthetic refrigerants.

The amount of cooling depends on the weather. The manual says the cooler works best on hot, dry days. The brochure describes it as using the natural process of water evaporation to lower temperatures.

The main parts

  • Cooling pads. The brochure says the pads are up to 130 mm thick, and let water spread freely and evenly over the surface. They also filter impurities and pollens from the air.
  • Water pump. The brochure calls it self cleaning. It can spin in the opposite direction to clear a blockage. Some models use the SynchroDrive pump.
  • Fan and motor. The brochure says the direct drive motor sits within the cooled air stream, which keeps it running on the hottest days.
  • Tank. Water collects in a tank at the base. The manual lists 12 litres for Contour and Promina, 15 litres for Advance and Advance Plus, and 32 litres for AD models.
  • Winter seal. The manual says Contour and Advance Plus have a motorised winter seal. On Contour models, it is the ServoSeal damper, which seals the ducting when the cooler is off.

What happens when you press start

A Brivis cooler does not blow air straight away. When you turn it on with the fan and pump, it starts an automatic pre-wet. The manual explains that this makes sure the pads are thoroughly wet before the fan starts, so warm air is not blown into the house at the start.

First the tank fills with water if needed. Then the pump wets the pads, and on Contour models the ServoSeal damper opens. Finally the fan starts. The manual says the whole process can take up to 8 minutes before cool air comes from the outlets. During pre-wet, a Networker shows the message “Pre-Wetting cooler pads – Please Wait!” and the fan symbol flashes.

A new smell

The air may smell a little different at first. The manual says new cooling pads can give off a mild odour while they settle in. This is normal, and it fades quickly as the pads are flushed during use. However, the FAQ adds that an odd smell may also mean the unit needs a service.

What happens when you switch off

Shutting down takes a while too. On Advance, Promina and Contour units, and on AD units fitted with the optional valve, the manual says the tank empties for a period after the cooler turns off. Advance, Promina and Contour models also wash the tank with clean water at the end of use. At the same time, Contour models close the ServoSeal damper to reduce draughts. The manual puts the flush and ServoSeal at about 1 hour after the cooler is turned off.

How do I operate Brivis evaporative cooling?

How you run it depends on the wall control. The manual covers three: the Brivis Networker, the programmable wall control and the manual wall control. Check which one is on your wall, then follow its steps below. For the controls in more depth, see the Brivis controller manual guide.

With a Brivis Networker

The Networker runs the whole system and senses the room temperature. A flashing heart symbol shows that it is the one sensing.

For Auto mode, turn the Networker on with the On and Off button. Then press Auto until Auto appears, and turn the dial to set the comfort level. Turn it up for a cooler comfort level and down for a warmer one. In Auto, the Networker turns the pump on or off and changes the fan speed to hold that level. It remembers your settings for next time.

For Manual mode, press Auto until MANUAL appears. Press Key 1 to turn the fan on and Key 2 to turn the pump on, then turn the dial to set the fan speed. The manual says the pre-wet takes about 8 minutes before the fan starts. To run the fan alone, press Key 2 again so the water droplet symbols disappear.

Why Brivis prefers Auto

The manual gives its reasons for choosing Auto over Manual. Power and water use vary with the comfort level, which is harder to hold in Manual. The unit runs only when it is needed, and it keeps the comfort level as conditions change. In addition, the fan only runs as fast as needed, so outlet noise stays low. That slower speed also wets the pads more evenly and gives cooler air from the outlets.

Setting the Networker timer

Set the time and day first. With the Networker off, press Key 5, labelled Clock. Turn the dial to the right time, press Key 1 for the day, then press Key 5 again to save. Where two Networkers are fitted, only the master can set the clock.

To have the cooler turn itself on, press PROG so ON TIME flashes. Turn the dial to the start time, adjust the fan speed or comfort level, press Key 3 to activate the timer, then press PROG to save. To have it turn off, do the same with the cooler running, setting OFF TIME instead. Press Key 3 to cancel either timer.

Locking the Networker

To stop anyone changing the settings, the Networker can be locked with a 4 digit PIN. To lock it, press FUNCTION and then Key 2 straight away, and enter your PIN. The screen shows System locked out, and a flashing padlock appears. If this is the first time, the manual says the factory PIN is 1111, and the PIN setting steps start from the same FUNCTION and Key 2 press, followed by MODE twice. After three wrong attempts, the Networker leaves the PIN screen and you start again. Where two Networkers are fitted, locking one locks both.

With a programmable wall control

This control has Auto and three Manual choices: fan and pump, fan only, and pump only. Press MODE to step through them. In Auto, use the up and down keys to choose a comfort level. The manual says the lower the number, the cooler the setting.

Its timer delays the On and Off key, in 1 hour steps from 1 to 12 hours. Press TIMER, set the hours while the timer light flashes, then leave it for 5 seconds. Press TIMER twice, or press On and Off, to cancel. When the timer turns the cooler on, it uses the settings from the last time it ran.

With a manual wall control

Press On and Off, and the power light comes on. Slide the COOL switch on to run the pump. The manual then says to allow 5 to 10 minutes for the pads to pre-wet before sliding the FAN switch on, which gives the greatest cooling straight away. Set the airflow with the fan speed dial. For ventilation only, slide COOL off so the pump stops and the fan keeps running.

Why do the weather and open windows matter?

Evaporative cooling needs dry air and a way out for the warm air. Both depend on how you set up the house, not just the controller.

Humid days

On humid days, the manual says the cooler works best with the fan on high and perhaps the pump turned off. If moisture builds up on tiles or hard floors, direct the airflow from the outlets across the ceiling rather than down at the floor, and check enough windows or doors are open. The manual also warns that if the pump is used, adequate ventilation is needed to stop condensation building up.

How much to open

The manual gives an opening area for each model. For example, Contour L36, Promina P36 and Advance F36D models need about 1.9 square metres on the highest fan setting, which it suggests as one door and a hinged window. On the lowest fan setting they need about 1.1 square metres. Larger models need more, up to about 3.4 square metres for the biggest in the table.

For reference, the manual counts a fully open door as 1.6 square metres, a hinged window as 0.3 and a sliding window as 0.7. Half open, an opening gives only half that area, so you would need more of them.

Cooling part of the house

To cool one area, the manual says to concentrate the openings there. Cool air flows towards the open windows and doors, cooling the rooms it passes through. On hot, windy days, open windows on the sheltered side of the house. Start the cooler early, too, so heat does not build up inside.

You can run the system while you are out. The manual’s FAQ says this is fine, provided the required openings are left open.

How much water does Brivis evaporative cooling use?

Brivis does not give one figure, because the answer changes with conditions. The manual explains that the more water a cooler can evaporate, the more cooling it can give. The evaporation rate depends on the weather, the size of the cooler, the fan speed or air velocity through the pads, and the condition and type of pad. On top of evaporation, some water is also let go to keep the tank water fresh.

How each series keeps its water clean

As water evaporates, salts and sediment stay behind. Each Brivis series deals with that its own way, according to the manual and the brochure.

  • AD series. Uses a bleed off method, so water runs continuously from the drain outlet while the unit is on.
  • Advance and Promina. Use Running Refresh. The manual says they flush the tank about every 20 cycles of the pump, so you will see water leave through the overflow pipe.
  • Promina AutoRefresh. The brochure says it controls how much fresh water is added, and flushes the whole tank after a set number of fill cycles.
  • Contour AquaSave. An inbuilt water conditioner keeps the water clean, so Contour models do not dump water during operation.

The AquaSave figure

The brochure gives one published figure. It says AquaSave reduces wastage and saves up to 45 percent on water consumption, compared with a conventional evaporative cooler with a bleed system. That figure applies to the Contour, which is the only range with AquaSave.

Some models also run FreshStart. The brochure says that when cooling is no longer needed, it removes stagnant water and sediment before the next start. For a wider look at what affects water use, see how much water evaporative cooling uses.

What can a Brivis evaporative cooler not do?

The manual and brochure are clear about the limits.

  • It cannot share ducts with gas heating. The manual says the technologies differ, and evaporative cooling needs larger ductwork. For heating, see the Brivis ducted heating guide.
  • It cannot cool as much on humid days. The manual says performance drops when the weather is very humid.
  • It cannot work with the house shut up. Without open doors or windows, the warm air has nowhere to go.
  • It cannot reuse the same air. The brochure says air is continuously refreshed and never recirculated, which is why the house must vent.

For the basics of the technology across all brands, see what evaporative cooling is.

Messages and resets on a Networker

If something unusual happens, the Networker scrolls a cooler fault message with a code. The manual advises writing it down first. If Reset appears beside Key 4, press it to restart the cooler. If the cooler does not resume normal operation, or the message returns, contact Brivis Service. The manual also says that if the time and room temperature show but the word COOLER does not, the cooler has lost communication with the Networker and needs a service call.

Quick checks before calling

The manual’s save a service call list covers the basics. If the unit blows warm air, check the water supply tap is on at the cooler and the pump is selected. If the fan will not start, check the power, the wall control setting, the fuse in the meter box and any time delay, which can be up to 8 minutes. If a fuse has blown or a breaker keeps tripping, leave it to a licensed electrician. If the Networker display is blank, check the power point and the circuit breaker. If no air comes from some vents, the manual says to contact the service department.

Servicing and the safety line

Brivis recommends a service every 2 years at a minimum, by a person trained in servicing Brivis coolers. The manual lists what a service covers, from the pads and tank to the pump, fan and water levels. It also says only a licensed person should install, maintain or remove the cooler.

Do not climb onto the roof or open the cooler. Work inside the unit or on its electrical supply is for a licensed electrician or technician. Energy Safe Victoria says unqualified electrical work is extremely dangerous and illegal. For what a cooler service involves, see evaporative cooling service.

Where is the Brivis evaporative cooling manual?

The Brivis evaporative cooling manual used here is the Brivis Evaporative Air Coolers Operation Manual, Issue F, August 2019, published by Rinnai Australia. It lists the models it covers on its warnings page. Check your model number on the installation record or the unit, then follow the section for your wall control. In short, open enough windows, choose Auto where you can, and let the pre-wet finish before expecting cool air.