Brivis Controller Guide: What the Networker Screen Means and How to Reset It

Reading time 13 minUpdated 28 Nov 2026For Australian homesBy Checked against sources by our review team, 28 Nov 2026
Short answer

A screen dictionary for the Brivis Networker wall controller, from the Brivis owner’s manual: what a blank screen, Busy, the padlock, Temporary and the spanner mean, how to set the time, program the week, run the fan only, stop it turning off unexpectedly and reset it in the right order.

A Brivis controller, such as the Brivis Networker wall control, runs your ducted gas heating and tells you what the heater is doing. When the screen shows something unexpected, start with what the screen itself is telling you. This guide starts with a screen dictionary, then covers setting the time, programming, fan only mode, a controller that keeps turning off, and how to reset it.

This page works as a plain English Brivis controller manual. The source is the Brivis Heating Owner’s Manual, part number B021918, Issue F, May 2016, copyright Brivis Pty Ltd. It covers the Brivis StarPro Max, SP, BX5 and Classic heaters with the Networker. Rinnai now sells Brivis ducted heaters. Some steps differ between heater models, and the manual says so where it matters.

What is my Brivis Networker screen showing?

The Networker’s screen shows the time at top left, the day on the left, the selected appliance at the bottom, and the room temperature. Messages can also scroll across the top. Here is what the manual says about each symbol.

What you seeWhat it means
Flame symbolThe heater is switched on. It flashes during cooldown at the end of a heating cycle.
Fan symbolThe heater is switched on. It also flashes during cooldown.
Flashing heart, bottom rightThe room temperature is being sensed from this Networker.
Thermometer with a markerCurrent room temperature, with the set temperature marked beside it.
PadlockThe child proof lock is set. See below.
SnowmanAdd-on cooling only. The compressor is running. Flashing means a safeguard delay.
SpannerSomething unusual has happened, or a service is due. See below.
Solid arrow beside a zoneThat zone is open and receiving heat.
Flashing arrow beside a zoneThat zone has reached its temperature and closed.
No arrow beside a zoneThat zone is not selected.

A blank screen

The Networker needs no batteries, the manual says. It links a blank screen to the heater’s power supply or the thermostat cable.

The manual’s checks are simple. Make sure the heater’s power point is plugged in and switched on. Then test that power point with another appliance. The manual also mentions the thermostat cable, which runs from the heater to the controller. Inspecting or repairing that cable is not an owner job.

A power cut can also catch you out. The manual says if power is off for more than two to three hours, the time and day may need resetting once power returns.

The Busy message

On StarPro Max, SP and BX5 heaters, the manual says a “busy” code appears at the top of the screen while the heater makes its re-ignition attempts. The heater tries up to four times to light before it locks out.

Busy can also appear after the heater has not run for a long time, after any interruption to the gas supply, or on first use. The manual explains that air may need to be purged from the gas pipe. So give it time.

If the heater does lock out, a spanner appears. The manual says reset may need pressing several times, depending on how long the air takes to clear. If it still will not light, the heater error code tells you more, and the Brivis heater error codes guide decodes it.

The padlock symbol

A padlock means the child proof lock is on. The manual says a flashing padlock shows the Networker is locked, so settings cannot be changed. To unlock it:

  1. Press the Function button, then Key 2 straight away. The screen asks for your PIN to unlock.
  2. Enter your user PIN with Keys 1 to 5. The screen shows “System unlocked!”.
  3. If you make a mistake, press the Auto key to clear the digits and start again.

You get three tries. After the third invalid PIN, the Networker leaves the PIN screen and you repeat the process. If nobody has changed the PIN, the manual says the current PIN is 1111. If two Networkers are fitted, locking or unlocking one does the same to the other.

Setting or changing the lock PIN

The lock uses a four digit PIN. To set a new one, the manual’s steps are:

  1. Press Function, then Key 2 straight away. Do not enter numbers yet.
  2. Press the Mode key once. The screen asks for a master PIN. Do not enter numbers yet.
  3. Press the Mode key again. The screen asks for the current user PIN. Enter it.
  4. Enter the new four digit PIN using Keys 1 to 5, then enter it again to confirm.

The screen shows “Valid PIN, PIN altered” when it works. Press On and Off at any time to leave. To lock the system, press Function then Key 2 and enter your PIN. The screen shows “System locked out!”. With two Networkers, the PIN can only be set from the master.

Temporary flashing

Temporary flashing is normal. The manual says it appears when you change the temperature with the dial while the Networker is running its Auto Program. The word flashes at the bottom of the screen until the current program period ends. Then the Networker goes back to its program by itself.

Changing a zone setting during Auto also counts as a temporary change. To cancel early, press Key 2, which becomes the Cancel key while Temporary is showing.

The spanner symbol

However, the spanner has two meanings. If something unusual happens, press Function then Key 1, and a message with a code scrolls across the screen. Write it down before doing anything else, as the manual suggests. Push Function then Key 1 again to repeat the message.

The spanner also flashes once a second when the logged fan hours mean a service is due. The manual says pressing Key 4 on the master controller clears that reminder.

How do I set the time on a Brivis Networker?

Setting the clock matters, because the Auto Program runs on it. The manual’s steps:

  1. Press On and Off to turn the Networker off.
  2. Press Key 5 (clock). The screen shows “Clock setting mode” and the clock flashes.
  3. Turn the rotary dial to set the time.
  4. Press Key 1 (day) until the right day shows on the left, such as “Mon”.
  5. Press Key 5 (clock) again to save.

With two Networkers, only the master can set the clock and change programs. The manual says you can spot the master by the word “clock” beside Key 5 when both controllers are off.

How do I program a Brivis Networker?

The Networker has two ways of running the heater: Auto and Manual. The Auto key switches between them.

The built in Auto Program

Out of the box, the Networker holds a preset program for the whole week. The manual lists it like this:

PeriodTimeHeating
Wake6:00am20
Leave9:00amOff
Return4:00pm20
Presleep9:30pm20
Sleep10:00pmOff

To run it, turn the Networker off. If you have more than one appliance, press the Mode key until “Heater” shows. Turn the Networker on, then press Auto until “Auto Program” appears. The manual recommends leaving the system off overnight, to save energy and reduce your gas bill.

Changing the program for good

  1. Turn the Networker off and check it is in heating mode.
  2. Press the Prog key. “Program” and the clock start flashing.
  3. Press Key 1 (day) to choose the weekday block or the weekend block. The Networker treats all weekdays as one block and both weekend days as another.
  4. Press Key 2 (period) to choose Wake, Leave, Return, Presleep or Sleep.
  5. Press Key 3 (Time or Temp) and use the dial to change the time or the temperature. A temperature of “- -” turns the heater off for that period.
  6. Use Keys 4 and 5 to choose zones for that period, if zones are fitted.
  7. Repeat for other periods and the other block, then press Prog to save.

Press Prog again to review what you saved, and once more to finish the review.

Skipping ahead and manual operation

Key 2 (Adv Period) jumps to the next period early, for example from Wake to Leave. Press it again to cancel.

For manual operation, turn the Networker off, select Heating with the Mode key, turn it on, and press Auto until “Manual” appears. The set temperature shows at the top. Turn the dial to change it. The manual notes the heater will not start until the room drops below that set temperature. The Networker remembers your manual settings for next time.

What does fan only mode do on a Brivis controller?

Fan only runs the heater’s fan without heat, to move air through the house. The manual mentions it for circulating air, and for running air quality devices such as electronic air filters, where fitted. It also says the feature has to be set up at installation.

With the Networker off, press the Mode key to select Heating, then press Key 1 (fan). A spinning fan symbol and a speed column appear. On StarPro Max and Plus heaters, the dial changes fan speed. On Classic heaters, the manual says the fan runs at full speed whatever the dial shows.

With the Networker on and already heating, on StarPro Max and Plus only, pressing Key 1 keeps the fan running between heating cycles. The heater controls its speed, which stays low and steady. Press Key 1 again to turn the fan off.

If the fan runs non stop and you did not ask it to, the manual’s troubleshooting table says to check that fan only has not been selected. It also lists open vents, a clean return air filter and crushed ductwork as things to check. Ductwork damage is a job for a service provider.

Cooler owners use the same steps with Cooling selected, if add-on cooling is fitted. For an evaporative system, see how Brivis evaporative cooling works.

Why does my Brivis controller keep turning off?

The program may simply be doing what it was told. The manual’s troubleshooting table covers a unit that turns on or off when you do not want it to, with a simple answer: check the automatic settings, reprogram them if needed, or switch to manual mode.

First of all, look at the Auto Program. For example, the preset turns the heater off at 9:00am and 10:00pm. A Temporary change also ends when the current period finishes, so the heat can drop back to the program setting.

Next, check the set temperature, because it decides when heating starts. If the room is already warmer than the setting, the heater stays off until the room cools below it. On zoned systems, a flashing zone arrow means that zone has reached temperature and closed.

Zones can also look like the controller switching off. The manual says Zones A and B use Key 4, and Zones C and D use Key 5. Pressing a zone key selects or deselects that zone. A zone left deselected gets no heat at all.

Then think about power. If the power goes off while the heater runs, the manual says safety mechanisms shut off the gas, and the heater resumes when power returns. A long outage can leave the clock wrong, which throws the program out. Reset the time and day.

A quick Brivis controller not working checklist

  • Blank screen: check the heater’s power point, and test it with another appliance.
  • Padlock showing: unlock it with your PIN.
  • Busy showing: wait while the heater tries to light.
  • No heat at the set temperature: check the room is colder than the setting, and the gas is on at the heater and the meter.
  • No air from some vents: the manual says this is very likely an installation issue, especially with zoning, so contact your installer.
  • A whistling noise: check the return air grille and filter are clean.

If none of that explains it, and a spanner or code appears, read the code first. The Brivis ducted heating troubleshooting guide covers heater faults that are not about the controller.

How do I reset a Brivis controller?

A Brivis controller reset follows the order the manual gives, and each step runs through the Networker. Changing the program is not a reset. Use the programming steps above. Use each step only if the one before does not work.

  1. Press Reset on screen: on StarPro Max, SP and BX5 heaters, “Reset” may appear beside Key 4 while a message scrolls. Press Key 4 to restart the heater. If you do not see Reset, press Function then Key 1, and Reset appears beside Key 4.
  2. Turn the Networker off for two minutes: use On and Off to switch it off, wait two minutes, then switch it on.
  3. Power off at the heater: turn off the power point beside the heater for about one minute, then back on.

If normal operation still does not return, the manual says to contact Brivis Service with the model and a description of the problem.

Classic heaters reset differently

For Classic models that have not blown warm air after 30 minutes, the manual describes a different reset. Turn the wall control off, wait five seconds, and turn it back on. Do this three times within one minute.

The manual also says that if a Classic heater shows normal operation on screen for more than eight minutes without fan or heat, try turning the Networker off and on, then the heater, as above.

What a reset will not fix

A reset clears a stored fault so the heater can try again. It does not fix the cause. The manual says error 50, a lockout after four ignition attempts, will probably lock out again if the condition has not been fixed. Repeated lockouts need a licensed gasfitter.

Which Brivis controller do I have, and where is its manual?

Brivis has used several Networker wall controllers over the years. Rinnai’s Touch Wi-Fi Kit manual shows pictures of the N-C1, N-C2, N-C3, N-C4, N-C6 and the N-C7 Touch. It lists only the N-C3, N-C6 and N-C7 Touch as compatible with the Touch Wi-Fi module.

The controller described on this page has a rotary dial, five numbered keys, and Function, Mode, Prog and Auto keys. That matches the look of the N-C3 and N-C6 in the Rinnai pictures. The N-C7 Touch is a touch screen and works differently. The owner’s manual used here does not name an N-C1, so it cannot confirm steps for that controller. Check the N-C1’s own documents.

Two Networkers on one system

The manual says two Networkers can be fitted, one set up as the master and the other as the slave. Heater settings are shared, so a change on one shows on the other. Only the master sets the clock, changes programs and sets PINs. With zoning, the two controllers can also act as remote temperature sensors, which your installer can set up.

If you are after an old Brivis wall controller manual PDF, start with the heater’s model number on its rating label. Rinnai lists Brivis ducted gas heaters on its Australian website and publishes product manuals there. The Brivis ducted heating owner guide lists the heater ranges.

When is it not a controller problem?

The controller is the owner’s side of the system. The heater, its gas supply, burner and flue are not. Never open the heater, remove its panels or touch the gas valve, burner or flue. Gas work, including fault finding on the gas side, is for a licensed gasfitter.

Energy Safe Victoria says to have a gas heater serviced at least once every two years by a qualified gasfitter. Each other state and territory has its own gas safety regulator. The Brivis manual also gives two years as the service interval. To see what a visit includes, read what a gas heater service visit covers.

In short, a Brivis controller explains itself once you know its symbols. Busy and Temporary are normal, the padlock is a lock, the spanner is a message, and a blank screen means power. Reset in the order the manual gives, and leave anything on the gas side to a licensed gasfitter.