Short answer

For a Bonaire Slimline controller reset, press the up and down buttons together until CLD appears, then press on/off to start. Turning the power off and back on also resets it. Bonaire links Er2 to the pump or water supply, Er3 to the motor and Er5 to the dump system. Repeat errors need a service call.

The cooler has stopped, and the slim wall controller in the hallway shows an error instead of a speed number. The house is warming up and you want the cooler back on without waiting days for a technician. A Bonaire Slimline controller reset is quick, and it is the first thing Bonaire asks you to try.

Bonaire’s troubleshooting for controllers sheet gives the exact button steps for the Slimline. Bonaire’s service booking page lists what the Er2, Er3 and Er5 codes mean and what to do about each one.

This guide explains how to do the reset, what each error tells you, which checks are safe to make first and when to stop and book a service.

How to do a Bonaire Slimline controller reset

Bonaire gives two ways to reset a Slimline controller when an error is showing.

Method 1, the button reset

  1. Note the error that is showing on the screen, so you can tell a technician later if needed.
  2. Press the up and down buttons together. Keep holding them until CLD appears on the screen.
  3. Press the on/off button to start the cooler again.

Method 2, the power reset

Bonaire says powering the unit off and then back on again will also reset it. For the Er5 error, Bonaire suggests turning the power off at the appliance for 30 seconds and then back on. It notes you can do this by turning the household mains power off at your switchboard.

If you use the switchboard, remember that other appliances, clocks and timers in the house will also lose power.

Try only once or twice

A reset clears the message, but it does not fix the cause. If the same error comes back soon after a reset, the controller is reporting a real problem. Repeated resets will not help and can hide what is going on.

What do Er2, Er3 and Er5 mean?

Bonaire’s service page lists three Er codes for its cooling products. For Er2 and Er3, the fix it gives is the up and down button reset used on the Slimline. For Er5, it suggests a power reset first.

Er2, no detection of pump operation

Bonaire says Er2 means the controller cannot detect the pump running. The likely causes it gives are a pump problem or no water in the appliance. Bonaire’s action is to press the up and down buttons together until CLD displays.

Before resetting, check the obvious water causes from the ground. Is the water turned on at the house? Do the other taps run normally? Has there been plumbing work or a water outage in the street? If the water was off, a reset once it is back on may be all that is needed.

Er3, no detection of motor operation

Bonaire says Er3 means the controller cannot detect the motor running, and its note for Er3 reads motor not rotating. The action again is to press the up and down buttons together until CLD displays.

If Er3 returns after a reset, the motor side of the cooler needs a technician. Do not go onto the roof to look at the fan or motor yourself.

Er5, dump system not operating

Er5 points to the dump system, which drains water from the cooler’s tank. Bonaire suggests a power reset first. Turn the power off to the appliance for 30 seconds and then back on, then reset the controller. If the problem persists, Bonaire says to book a service call.

Navigator users see different codes

If your wall controller is a Navigator, the same faults show with different labels. Bonaire lists CO 22 for no pump operation, CO 33 for no motor operation and CO 55 for the dump system. On a Navigator, Bonaire says to press ENTER once to clear the error, then the on/off button to start.

Our guide on how to reset Bonaire Navigator controls covers the Navigator in more detail.

Safe checks before and after the reset

You can do all of these from inside the house or the yard:

  • Confirm the property has power and no safety switch has tripped at the switchboard.
  • Check the water supply to the house is on, especially for Er2.
  • Make sure the controller is in MANUAL mode, which Bonaire says is the most common mode.
  • On a Slimline, the speed shows as a number from 1, the lowest, to 12, the highest. After a reset, set a speed you would normally use.
  • Open enough external doors and windows before you restart the cooler.

Do not climb onto the roof to inspect the pump, motor or drain. Bonaire’s own documents point owners to a service call when these errors persist.

What is normal after a reset?

After you clear the error and press on/off, the cooler restarts in the mode you choose. Bonaire’s documents do not give a set start-up time for every Slimline model, so allow some time for water to reach the pads before judging how cool the air is.

If the error does not return and the air cools normally, the reset has done its job. Keep an eye on the controller over the next few days in case the same code comes back.

Bonaire reset: when to call a licensed technician

Book a service through Bonaire or a qualified technician if:

  • Er2, Er3 or Er5 returns after one reset.
  • Er2 shows even though the water supply is definitely on.
  • Er3 shows and you cannot hear the fan running at all.
  • Er5 persists after a 30 second power reset, as Bonaire advises.
  • The controller screen is blank, flickering or not responding to any button.
  • You notice burning smells, smoke, tripping safety switches or water coming from ceiling vents.

Pump, motor, drain and electrical repairs are roof work and electrical work. Leave them to a licensed technician.

Related answers

Frequently asked questions about a Bonaire Slimline controller reset

What does CLD mean on a Bonaire Slimline controller?

CLD is what the Slimline shows when the reset works. Bonaire says to hold the up and down buttons together until CLD appears, then press on/off to start the cooler.

Will turning the power off reset a Bonaire Slimline?

Yes. Bonaire says powering the unit off and back on will also reset it. For Er5, Bonaire suggests leaving the power off for 30 seconds, which you can do at the switchboard.

Why does Er2 keep coming back?

Bonaire links Er2 to the pump or to no water in the appliance. If the water supply is on and Er2 still returns after a reset, book a service call.

Is a Slimline reset the same as a Navigator reset?

No. On a Navigator, Bonaire says to press ENTER once to clear the error, then on/off. The Slimline uses the up and down buttons together until CLD appears.

Bonaire reset: the key points

A Bonaire Slimline controller reset takes seconds. Hold up and down together until CLD appears, then press on/off, or switch the power off and on again.

The error code matters more than the reset. Er2 points to the pump or water supply, Er3 to the motor and Er5 to the dump system. If any of them come back, book a service rather than resetting again.