The reverse cycle defrost cycle explained from the makers’ own manuals: why ice forms on the outdoor unit, what the defrost does and how long it lasts, what you see and hear, heating below zero, a frozen outdoor unit, water dripping in heat mode and when it is not normal.
Part of our Air Conditioner Maintenance and How Home Systems Work.
The reverse cycle defrost cycle is the reason a split system can stop heating on a cold morning, go quiet indoors and send a puff of steam off the outdoor unit. It is an automatic routine, and the manufacturers’ manuals describe it as normal. This page explains it as cause and effect: why ice forms, what the defrost cycle does about it, what you see while it runs, and the signs that something is not normal.
Each manufacturer fact below is credited to the brand that published it, from its owner manual or its Australian website. The licence and electrical safety points come from ABLIS and Energy Safe Victoria. Details differ between brands and models, so check the manual for your own unit as well.
Why does ice form on the outdoor unit?
In heating mode, a reverse cycle air conditioner works as a heat pump. Fujitsu’s operating manual for the ASTG09KMTC and ASTG12KMTC explains that it absorbs heat from the outdoor air and transfers it to the indoor unit.
Mitsubishi Electric Australia’s guide to the defrost cycle says moisture in the air can freeze on the outdoor heat exchanger and reduce the unit’s efficiency. Fujitsu’s manual says frost may form when the outdoor temperature is very low with high humidity. Mitsubishi Electric’s MSZ-AP operating instructions put it the same way: frost forms when the outside temperature is too low and the humidity too high.
Why the ice matters
The manuals agree that ice is the problem. Fujitsu says frost could reduce the operating performance of the product. Actron Air’s LM7-2 and LM24-2 wall controller manual says a gradual build up of frost reduces the performance of the air conditioner. So the unit has to clear it.
What does the defrost cycle do?
The defrost cycle melts the ice on the outdoor coil, then lets heating carry on. Mitsubishi Electric calls it an automatic function that melts accumulated ice and keeps the system working effectively. Actron Air’s manual says the microprocessor detects the frost build up and activates defrost mode on its own. You do not need to press anything.
What happens inside the system
According to Mitsubishi Electric, heating pauses while the defrost runs. The indoor and outdoor fans stop, so cold air is not blown inside. Meanwhile, the compressor keeps running to generate heat and melt the ice. The cycle continues until the outdoor heat exchanger is warm enough and the ice has cleared.
How long it lasts
Each manufacturer gives its own figures for its own models:
| Manual | What it says about defrost time |
|---|---|
| Hitachi, RAS-S25YHAB and RAS-S35YHAB | About once an hour when frost forms, 5 to 10 minutes each time, 20 minutes at most, or 15 minutes with a multi outdoor unit |
| Fujitsu, ASTG09KMTC and ASTG12KMTC | The indoor unit stops for a maximum of 15 minutes |
| Mitsubishi Electric, MSZ-AP | Completed in a maximum of 10 minutes |
| Kelvinator, KSV25CRG to KSD80HRG | The indoor unit stops for a maximum of 10 minutes |
Mitsubishi Electric adds that how often a unit defrosts depends on several things, including the outdoor temperature and humidity, how hard the system is heating, and its condition and cleanliness.
What will I see and hear during a defrost?
The manuals list several signs, and none of them is a fault on its own.
Heating stops for a while
Warm air stops coming out of the indoor unit, and the indoor fan may slow or stop. Mitsubishi Electric’s MSZ-AP instructions say the horizontal vane moves to the horizontal position during defrost, and the fan speed drops or the fan stops. Actron Air says the indoor fan will not run for several minutes, to avoid blowing cold air into rooms.
A lamp or symbol changes
- Hitachi’s S Series manual says the OPERATION lamp blinks in a cycle of 2 seconds on and 1 second off during defrost.
- Actron Air’s wall controller flashes the HEAT indicator every 10 seconds.
- Kelvinator’s CRG and HRG user manual says the defrost light blinks.
- Fujitsu’s manual says an indicator on the indoor unit blinks during the defrost.
Steam and mist
Steam can rise from the outdoor unit. Hitachi explains it as water from the defrost evaporating. Fujitsu and Actron Air list it as normal too. When heating starts again, Kelvinator’s CRG and HRG manual says mist may come from the indoor unit, from moisture produced by the defrost. Carrier’s manual describes white mist at the same point.
Unusual sounds
Actron Air’s manual says a whooshing noise may come from the outdoor unit as the refrigerant changes direction during defrost, and that the compressor may sound louder than normal. Fujitsu describes a sizzling sound in heating, produced by the automatic defrost.
Does reverse cycle heating work below zero?
The manuals answer this with operating ranges. Several list outdoor temperatures below zero for heating:
- Toshiba’s owner’s manual for the Seiya RAS-07 to 18E2KV2G-A gives a heating range of minus 15 to 24°C outdoors.
- Carrier’s owner’s manual for its 42QHG wall units also gives minus 15 to 24°C outdoors in heat mode.
- Kaden’s KSI Series manual gives minus 15 to 30°C outdoors for heating.
So these units are designed to heat below zero, within those limits. Outside the range, Carrier says safety protection features may activate and stop the unit.
Why heating gets weaker as it gets colder
Working is not the same as working at full output. Fujitsu’s manual says heating performance drops as the outdoor temperature drops, because the unit draws its heat from outdoor air. If heating feels short, Fujitsu suggests using another kind of heater alongside it.
Others say similar things. Toshiba’s Seiya manual suggests another recommended heater when the outdoor temperature is too low. Actron Air’s manual says supplementary heating may be used when it is about 7°C or colder outside. Mitsubishi Electric also says outdoor temperature and humidity affect how often a unit defrosts, and each defrost pauses heating.
Tips the manuals give for cold weather
Actron Air suggests starting the system a couple of hours earlier than usual on a cold day, or leaving it running overnight at a lower setting. Carrier says that for outdoor units with an auxiliary electric heater, it strongly recommends keeping the unit plugged in at all times when it is below 0°C outside. For more ways to heat well, see the guide to using reverse cycle heating efficiently.
What should I do if my split system outdoor unit is frozen?
Light frost on the outdoor unit on a cold morning is not a fault. That frost is what the defrost cycle exists to deal with. The unit is built to clear it, so the first step is to let it.
Do not chip or melt the ice
Mitsubishi Electric’s guide says not to try makeshift ice removal. It warns that pouring hot water on it or chipping at the ice can damage the system. Mitsubishi Electric’s MSZ-AP manual and Kelvinator’s CRG and HRG user manual also say not to use any means to speed up defrosting other than those the manufacturer recommends.
Help the unit help itself
- Keep the area around the outdoor unit clear. Mitsubishi Electric mentions privacy screens, panels and garden structures as obstructions to avoid.
- Mitsubishi Electric recommends the outdoor unit sits at least 100 mm off the ground.
- Toshiba’s Seiya manual says to place the outdoor unit where it will not be hit by snow drifts or build ups of leaves and other debris.
Raising or moving an outdoor unit is installation work, and the ABLIS refrigerant handling licence covers installing air conditioning equipment, so leave it to a licensed technician.
When frozen is not normal
The manuals describe defrosts that end within minutes. So if ice stays after the unit has defrosted, keeps coming back while heating stays weak, or a defrost never seems to end, treat it as a problem. In those cases, turn the system off and call a licensed technician. Mitsubishi Electric lists the system’s condition and cleanliness among the things that affect defrosting, and only a technician can check inside.
If the indoor unit is blowing cold air rather than stopping, see the guide to a split system blowing cold air on heat.
Is water dripping from the outdoor unit in heating mode normal?
Yes. Water dripping from the outdoor unit in heating mode is normal, and the manuals say so. In heating, the ice and condensation on the outdoor coil have to go somewhere when they melt.
- Fujitsu’s manual says the outdoor unit may emit water produced by the automatic defrost.
- Actron Air’s manual says water from the outdoor unit is normal in heating, because water forms on the heat exchanger.
- Carrier’s installation section says a drain joint must be fitted at the bottom of a heat pump outdoor unit before it is bolted down.
Where the water should go
That drain joint lets the water leave from underneath the unit. So do not block the bottom of the outdoor unit, and keep the area around it clear as Mitsubishi Electric advises.
When water is a warning sign
Water from the indoor unit is a different matter. Mitsubishi Electric’s MSZ-AP manual lists water leaking or dripping from the indoor unit as a reason to stop using the air conditioner and consult your dealer.
When is a defrost not normal?
Put the manuals together and a normal defrost looks like this. It happens in heating mode, on cold or damp days. It lasts minutes, not hours. Heating then resumes on its own. Anything outside that pattern deserves a closer look:
- Heating that never resumes after the times listed above.
- A lamp blinking in a fault pattern instead of the defrost pattern your manual shows.
- Ice that stays on the coil after a defrost.
- Breakers tripping, burning smells or loud abnormal noises.
If you have a Daikin, the Daikin air conditioner troubleshooting guide covers its lamps. For general background, see what a reverse cycle air conditioner is.
Leave the inside to a licensed technician
Whatever the cause, the fix sits behind the unit’s covers. The Australian Government’s ABLIS service says a refrigerant handling licence is needed for work on air conditioning equipment that could release a fluorocarbon refrigerant. Energy Safe Victoria says unqualified electrical work is extremely dangerous and illegal, and to always hire a licensed electrician. The air conditioning repair guide explains what to have ready for the visit.
What is the short version?
Cold, humid air freezes onto the outdoor coil in heating. The unit senses it and runs a defrost, which pauses heating for minutes while the fans stop and the compressor melts the ice. You may see a blinking lamp, steam outside, water underneath and mist indoors when heating restarts. That is all normal. Let the unit clear its own ice, keep the outdoor unit clear and raised, and call a technician if defrosts never end or ice will not clear.