Ducted heating · Brivis · Error & Fault Codes

Brivis Heater Error Codes: Reading the Spanner and the Code Number

Reading time 15 minUpdated 28 Nov 2026For Australian homesBy Checked against sources by our review team, 28 Nov 2026
Short answer

On a Brivis Networker, a spanner shows first and the code hides inside a scrolling message. Learn whether the spanner is a fault or a service reminder, how to bring up the Heater Fault message, what each code number means in the Brivis manual, how to reset and when to call a licensed gasfitter.

Brivis heater error codes do not appear on their own. On a Brivis ducted gas heater with a Networker wall control, a spanner symbol shows first. Then a message scrolls across the top of the screen with a title and a code number. The spanner can also mean something else entirely: a service reminder based on running hours, with no fault at all.

So the order matters. First work out why the spanner is showing. Then bring up the message and find the code number inside it. Only then look the number up. This guide follows that order, and every meaning comes from the Brivis Ducted Gas Heater Operation Manual and the Brivis error code sheet, both published on Rinnai Australia’s website. For model history and other manuals, see the Brivis ducted heating owner guide.

What does Brivis error code 50 mean?

Brivis error code 50 means the heater has locked out after four ignition attempts. In other words, it tried to light the burner four times and failed each time, so it stopped for safety. The Brivis manual says you can clear it with the reset button, but the error is likely to come back unless the cause has been fixed.

The cause Brivis points to first is gas supply. Check the gas is on at the meter and at the heater’s gas cock, and check whether other gas appliances are working. The full checks for this Brivis heater fault code 50 are in the code 50 section below.

Why is the spanner showing on my Brivis controller?

The Brivis manual describes two reasons for the spanner, and they need very different responses.

Spanner for a system event or fault

The manual says the Networker monitors the system while it runs. If it detects a system event, the spanner symbol displays and a notification or error message becomes available. This is the spanner that goes with a fault code. Go to the Heater Fault message section to read the code.

The spanner can also follow a failed start. The manual says that on SP and BX5C models, a busy code shows at the top of the Networker while the heater retries ignition. If re ignition is not successful, the heater locks out and a spanner icon displays.

Spanner as a service reminder

In contrast, the second reason is not a fault. The manual says that when the operating hours logged for an appliance reach a set duration, the spanner flashes once per second. A message then displays saying that fan run hours indicate it is time for a service call, followed by a support number.

So a flashing spanner with a fan run hours message is a reminder. It is not a fault code. It is still worth acting on, because the manual says the heater should be serviced at two year intervals. That service covers the burners, the ignition system, the fan assembly and the heat exchanger. For a plain explanation of the visit itself, read what a gas heater service visit covers.

How to tell which spanner you have

Read the message. A fan run hours message means a service reminder. A message titled Heater Fault with a code number means a fault. If you see the Brivis spanner symbol but no message, press Fn then Key 1 to bring the message up, as the next section explains.

How to clear the spanner

The manual’s steps to clear the spanner are short. Press Key 4 on the master controller, which is labelled RESET at that point. If the scrolling message and RESET are not showing, press Fn then Key 1 first. However, clearing a reminder does not replace the service. Similarly, clearing a fault spanner only helps once someone has fixed the cause.

What does the Heater Fault message on a Networker mean?

When the spanner shows because of a fault, the Brivis manual says error messages scroll across the top of the screen with a title and a code. Its example reads “Heater Fault H01 Code” followed by the code number, then a support number for assistance.

The part you need is the number after the word Code. That number is the Brivis error code, and it is what you look up in the list below. The manual does not explain what the H01 in the title stands for, so do not treat H01 as the error code itself. If you are looking up the Brivis Networker Heater Fault H01 code, read on to the number that follows.

How to bring up and record the message

The manual gives these steps to read available messages.

  1. Press the Fn button, then Key 1.
  2. Write down the date and the message.
  3. To see the message again, press Fn then Key 1.

The manual adds a useful note. If the message does not repeat, the event may have passed. It suggests writing down the date you noticed a message even if you could not capture its content.

What to have ready if you need help

The manual says messages hold information to help technicians fix the issue quickly, but many can be fixed by the customer using the error code section. If you need a technician, have three things ready: the message, the model and the type of appliance. Record the model number in the space the manual provides, or ask your installer. For a full tour of the Networker buttons and menus, see the Brivis controller guide.

What does each Brivis error code number mean?

The Brivis manual and its error code sheet list almost the same small set of codes. Only the manual includes 43. The manual covers Buffalo BX5C and BX3C, Compact CC3, StarPro SP6, SP5 and SP4, and Wombat 2PWN heaters. Here is the list in number order.

CodeBrivis meaningOwner checks listed?
40, 41, 42, 43Overheat condition, fan runs at maximum speedYes
46, 47Heater failed to ignite within the specified timeNo, service call
50Locked out after four ignition attemptsYes
53Locked out after multiple overheat occurrencesYes
55Heater failed to ignite within the specified timeNo, service call
56Locked out on the pressure switchYes, limited
Any other numberPossible fault with the electronic control moduleReset at power, then help

The manual introduces its code section by saying customers may safely fix these faults by working through the listed actions, and that if a fault persists, customers should contact customer care.

Brivis error code 40, and codes 41, 42 and 43: overheat

The manual says codes 40, 41, 42 and 43 indicate that an overheat condition has occurred. The fan will run at maximum speed, so a fan running at full speed can come with these codes.

Brivis lists three corrective actions.

  • Check there are enough outlets open on the duct system.
  • Check that each floor or ceiling register and its baffle is fully open and not restricting air movement.
  • Check the return air filter, if fitted, is the right size and clean, and that nothing has been placed in front of the return air grille.

The manual’s inspection section says a return air filter needs regular cleaning and should be checked fortnightly, because a blocked filter significantly affects performance. Its outlet guide also gives the number of outlets to open for best performance, so check that table if several outlets are closed.

Brivis error code 46 and 47: failed to ignite

The manual groups codes 46, 47 and 55 together. They indicate that the heater has failed to ignite within the specified time. The error code sheet lists the remedy for 46 and 47 as a service call, with no owner checks.

A heater that cannot light involves the gas valve, ignition and burner. Those are gas parts. So leave the heater off and book a licensed gasfitter.

Brivis error code 50: lockout after four ignition attempts

Code 50 means the heater has locked out after four ignition attempts. The manual says the reset button clears it, but the error will likely return unless the condition has been fixed. Brivis lists these corrective actions.

  • Check the gas supply is turned on at the meter and at the appliance gas cock. The error code sheet describes the gas cock as the manual valve that controls the flow of gas to the heater.
  • Check whether other gas appliances are working, such as a gas cooker or hot water service.
  • For LPG, check the cylinders have gas and the cylinder valve is open.
  • Check there is gas supply to the home by contacting the gas provider. There may be works in the area or a supply problem.
  • The heater may need a general service.

There is one situation where a lockout can be expected. The manual says several attempts may be needed to start the heater after a new installation, a long shutdown or an interrupted gas supply, because air has to be purged from the gas pipe. All models make up to four re ignition attempts before locking out, and the system may need resetting several times. If none of those apply, and the gas is on, a licensed gasfitter needs to find out why the burner will not light.

Brivis error code 51

Brivis error code 51 is not in the Brivis manual or the error code sheet. Those documents do not confirm it. Treat it as the manual treats any other code, covered in the other codes section: reset at the power supply, and if it persists, get help.

Brivis error code 53: lockout after repeated overheating

The manual says code 53 means the heater has locked out because of multiple overheat occurrences. It names the primary cause as typically insufficient airflow. So code 53 can follow when the overheat codes keep happening.

The corrective actions match the overheat codes. Check enough outlets are open, check registers and baffles are fully open, and check the return air filter and grille. Then reset the appliance. Brivis says that if error 53 persists, contact your installer.

If the airflow checks all look fine and 53 returns, there may be crushed or collapsed ducting. The manual’s troubleshooting table says to check that ducting has not been crushed or collapsed and to contact customer care if damage is evident. Ducts in the roof space or under the floor are best inspected by a professional.

Brivis error code 54

Neither the Brivis manual nor the error code sheet lists Brivis error code 54, so this page cannot confirm its meaning. Note the full message, reset once at the power supply as described below, and if the code returns, contact Brivis customer care or a licensed gasfitter with the message and model number.

Brivis error code 55: failed to ignite in time

The manual places code 55 with 46 and 47. All three mean the heater failed to ignite within the specified time. The error code sheet lists the remedy for 55 as a service call.

Checking that the gas is on at the meter and at the heater does no harm. The manual gives the same check for code 50. Beyond that, the ignition and burner side is gas work. Leave the heater off and book a licensed gasfitter.

Brivis error code 56: pressure switch lockout

Code 56 means a lockout has occurred on the pressure switch. The manual says it is usually caused by too much restriction on the flue pipe, or on the condensate drain on SP6 models. The error code sheet adds that gusty wind can cause the pressure switch to open because air blows back down the flue.

Brivis lists two checks: the flue pipe for blockages, and the condensate piping for blockages on SP6 models. Keep this owner side. Look at the flue terminal from the ground for leaves or nests, and look at the SP6 condensate tube where it is visible. The manual warns that the flue outlet can become very hot, so do not touch anything near it while the system runs. Anything on the roof or inside the flue is a job for a licensed gasfitter.

Any other Brivis code number

The manual covers every number it does not list with one note. Any other error code on the screen could mean the heater is not operating because of a malfunction or fault with the electronic control module. It says the error may be reset at the power supply, and if the error persists, contact customer care. That applies to any number outside the list above, including 51 and 54.

Can I reset a Brivis heater after a fault code?

Yes, within limits. The manual says that if heater operation has been interrupted, Reset may appear beside Key 4 while a message scrolls. Resetting may fix the issue. These are the manual’s steps, in order.

  1. If RESET is not showing next to Key 4, press Fn then Key 1. The error message scrolls and RESET appears.
  2. Press Key 4 to restart the heater.
  3. If the error persists, turn the Networker off with the power button and wait about two minutes. Turn it back on.
  4. If the error still persists, disconnect the heater from its power point near the heater unit and wait about one minute.
  5. Reconnect and switch on the power. If normal operation still does not return, contact customer care.

The manual says to contact customer care if, after resetting, the heater does not resume normal operation, the error persists, or other messages appear after clearing the fault.

Is it safe to keep resetting?

Work through the steps above once. The exception is the gas purge case described under code 50, where the manual expects several resets after a new installation, a long shutdown or a gas interruption. Outside that case, a code that returns is the heater telling you a fault remains. Repeated resets of an ignition or pressure switch lockout do not fix the cause.

After a power cut

The manual says that if power is interrupted while the heater runs, a safety function turns off the gas supply. When power returns, the heater can resume normal operation. If the power was off for more than about two hours, the Networker may need its time and day set again.

Which Brivis codes can I check myself, and which need a gasfitter?

The Brivis manual gives owners a short list of safe checks. Its “Before calling for assistance” section asks for these basic checks.

  • The flue terminal is in place whenever the unit runs.
  • The air intake, at the burner end of the heater roof panel, is clear of leaves and obstructions.
  • The flue terminal is clear of leaves and obstructions.
  • On SP6 models, the condensate tube is clear, since a blockage can shut the heater down.

Add to that the airflow checks for the overheat codes and the gas supply checks for code 50. The manual also says to check the circuit breaker in the meter box if the heater will not turn on.

Jobs for a licensed gasfitter

The manual says the appliance must be installed, serviced and removed only by a person with the licensing and insurance required by the relevant state or territory gas regulating authority. Energy Safe Victoria says homeowners must always use a licensed or registered gasfitter. Leave the heater off and book one for these.

  • Codes 46, 47 and 55, which Brivis lists as a service call.
  • Code 50 that returns after you have confirmed the gas supply is on.
  • Code 56 that returns, or any flue damage.
  • Codes 40 to 43 or 53 that return after the airflow checks.
  • Any excessive noise, smell or smoke. The manual says to turn the appliance off, isolate the power and contact a service agent.

Gas smell and carbon monoxide

Energy Safe Victoria’s gas emergency page says that if you smell gas, turn off the gas at the meter, or at the cylinder for LP gas, only if it is safe. Put out all flames, do not operate electrical switches, open doors and windows and keep people away. Then call your gas distributor using the details on your bill.

The Better Health Channel lists carbon monoxide symptoms such as headaches, dizziness, nausea and tiredness. Its advice is to open windows and doors, turn off the appliance and go outside to breathe fresh air. Call triple zero in an emergency, see your GP about any symptoms and have the heater serviced before you use it again. For more, read about carbon monoxide and gas heaters.

Where can I find the Brivis heater error codes manual?

Rinnai Australia publishes Brivis documents on its website. The operation manual’s warranty section names Rinnai Australia Pty Ltd. These are the two documents this page uses.

Older Brivis heaters and controllers may have their own manuals. In that case, use your heater’s model number to find the right one. If your symptom has no code, such as no airflow from some vents or a fan that will not stop, see Brivis heating troubleshooting.

What is the quick way to handle a Brivis code?

Brivis heater error codes follow one pattern. Check whether the spanner is a service reminder or a fault. Press Fn then Key 1 to bring up the message, and take the number after the word Code. Match it to the list: 40 to 43 and 53 point to airflow, 50 to gas supply, 46, 47 and 55 to ignition and 56 to the flue. Do the owner checks Brivis lists, reset as the manual describes, and call a licensed gasfitter when the code comes back.